Cooling Application Data - Outdoor Temperature oF 1

Model

D.B./W.B.

Cooling

75oF

80oF

85oF

90oF

95oF

100oF

105oF

110oF

115oF

￿

Capacity

 

 

 

 

 

 

 

 

 

 

 

75/

Total Cooling

20,680

19,550

18,470

17,470

16,530

15,660

14,850

14,110

13,435

 

62

Sensible Cooling

16,150

15,490

14,900

14,380

13,920

13,520

13,200

12,930

12,730

WH184

80/

Total Cooling

22,130

21,320

20,530

19,500

18,400

18,000

17,550

16,860

16,190

67

Sensible Cooling

15,690

15,200

14,770

14,390

14,060

13,780

13,560

13,380

13,260

 

 

85/

Total Cooling

26,320

24,910

23,560

22,290

21,090

19,960

18,900

17,920

17,000

 

72

Sensible Cooling

16,050

15,415

14,830

14,280

13,780

13,320

12,900

12,530

12,200

 

75/

Total Cooling

24,780

23,800

23,760

21,670

20,530

19,330

18,080

16,780

15,420

 

62

Sensible Cooling

19,600

19,090

18,570

18,040

17,495

16,940

16,380

15,800

15,220

WH242

80/

Total Cooling

26,450

25,940

25,300

24,520

23,600

22,550

21,360

20,040

18,575

67

Sensible Cooling

19,030

18,730

18,410

18,050

17,670

17,260

16,820

16,350

15,855

 

 

85/

Total Cooling

31,520

30,320

29,030

27,660

26,200

24,650

23,020

21,300

19,500

 

72

Sensible Cooling

19,490

19,000

18,470

17,910

17,315

16,680

16,020

15,320

14,585

 

75/

Total Cooling

31,600

30,290

28,930

27,540

26,100

24,620

23,100

21,530

19,920

 

62

Sensible Cooling

24,370

24,210

23,940

23,560

23,075

22,480

21,770

20,960

20,040

WH301

80/

Total Cooling

33,760

33,030

32,160

31,150

30,000

28,710

27,280

25,710

24,000

67

Sensible Cooling

24,000

23,830

23,650

23,485

23,310

22,900

22,360

21,690

20,880

 

 

85/

Total Cooling

40,220

38,600

36,910

35,140

33,300

31,390

29,400

27,340

25,200

 

72

Sensible Cooling

24,220

24,090

23,810

23,400

22,845

22,150

21,310

20,330

19,210

 

75/

Total Cooling

36,960

35,600

34,150

32,600

30,972

29,250

27,440

25,540

23,550

 

62

Sensible Cooling

28,730

28,320

27,820

27,220

26,530

25,740

24,850

23,875

22,800

WH361

80/

Total Cooling

39,475

38,820

37,960

36,880

35,600

34,100

32,400

30,500

28,375

67

Sensible Cooling

27,870

27,790

27,580

27,250

26,800

26,220

25,520

24,700

23,750

 

 

85/

Total Cooling

45,360

45,000

43,910

42,080

39,515

37,000

34,650

32,200

29,790

 

72

Sensible Cooling

28,570

28,190

27,670

27,030

26,260

25,350

24,320

23,150

21,850

 

75/

Total Cooling

46,330

43,420

40,680

38,350

36,100

33,920

31,800

29,770

27,800

 

62

Sensible Cooling

36,530

34,230

33,380

32,970

32,300

31,370

30,180

28,720

27,000

WH421

80/

Total Cooling

49,670

47,390

45,220

43,380

41,500

39,570

37,600

35,570

33,500

67

Sensible Cooling

35,900

34,900

33,020

32,900

32,600

32,110

31,430

30,560

29,500

 

 

85/

Total Cooling

59,150

55,450

51,740

48,590

45,600

42,770

40,090

37,570

35,200

 

72

Sensible Cooling

36,750

35,400

33,100

32,600

31,900

31,000

29,900

28,600

27,100

 

75/

Total Cooling

50,250

47,770

45,375

43,100

40,900

38,800

36,800

34,900

33,100

 

62

Sensible Cooling

39,550

38,500

37,500

36,525

35,600

34,700

33,875

33,050

32,300

WH483

80/

Total Cooling

53,700

52,050

50,400

48,700

47,000

45,250

43,500

41,700

39,900

67

Sensible Cooling

38,500

37,850

37,200

36,600

36,000

35,400

34,850

34,250

33,700

 

 

85/

Total Cooling

63,800

60,800

57,840

54,980

52,200

49,500

46,890

44,350

41,900

 

72

Sensible Cooling

39,250

38,300

37,300

36,325

35,300

34,250

33,200

32,100

31,000

 

75/

Total Cooling

58,200

56,300

54,200

51,800

49,100

46,150

42,950

39,450

35,700

 

62

Sensible Cooling

44,100

43,000

41,900

40,750

39,500

38,200

36,800

35,300

33,800

WH602

80/

Total Cooling

62,000

61,400

60,250

58,625

56,500

53,900

50,750

47,100

43,000

67

Sensible Cooling

42,800

42,200

41,600

40,800

39,900

38,900

37,800

36,600

35,600

 

 

85/

Total Cooling

74,000

71,750

69,150

66,100

62,725

58,900

54,700

50,125

45,150

 

72

Sensible Cooling

43,800

42,800

41,700

40,475

39,100

37,600

36,000

34,250

32,400

1Below 65oF, unit requires a factory or field installed low ambient control.

2 Return air temperature oF.

Capacity Multiplier Factors

% of Rated Airflow *

-10

Rated

+10

Total BTUH *

0.975

1.0

1.02

Sensible BTUH *

0.950

1.0

1.05

Heating Application Rating and Outdoor Temperature oF *

Model

 

-5o

0o

5o

10o

15o

20o

25o

30o

35o

40o

45o

50o

55o

60o

65o

 

BTUH

6,000

7,000

8,000

9,000

10,000

11,500

12,000

13,000

14,000

16,000

17,500

19,000

20,800

22,000

23,400

WH184

WATTS

1,600

1,630

1,680

1,700

1,730

1,760

1,795

1,820

1,860

1,890

1,920

1,950

1,980

2,020

2,040

 

COP

1.09

1.25

1.39

1.55

1.69

1.91

1.95

2.09

2.35

2.48

2.74

2.93

3.07

3.19

3.36

 

BTUH

6,960

8,030

9,090

10,160

11,230

12,775

13,360

14,430

15,500

18,700

21,910

24,280

26,080

27,880

29,680

WH242

WATTS

1,726

1,775

1,825

1,875

1,925

1,970

2,020

2,070

1,976

2,165

2,215

2,265

2,315

2,365

2,412

 

COP

1.18

1.32

1.45

1.58

1.70

1.90

1.93

2.04

2.29

2.53

2.88

3.14

3.30

3.45

3.60

 

BTUH

8,295

9,875

11,450

13,025

14,600

16,790

17,750

19,325

20,900

23,860

26,815

29,180

31,150

33,115

35,080

WH301

WATTS

2,100

2,165

2,230

2,290

2,350

2,400

2,470

2,530

2,662

2,650

2,710

2,770

2,830

2,890

2,952

 

COP

1.15

1.33

1.50

1.66

1.82

2.05

2.10

2.23

2.30

2.63

2.89

3.08

3.22

3.57

3.48

 

BTUH

12,490

13,970

15,445

16,920

18,400

20,900

21,830

22,825

24,303

28,510

32,720

35,820

38,180

40,550

42,920

WH361

WATTS

2,600

2,680

2,760

2,845

2,925

3,000

3,090

3,170

3,185

3,335

3,420

3,500

3,580

3,664

3,750

 

COP

1.40

1.52

1.64

1.74

1.84

2.05

2.07

2.10

2.23

2.50

2.80

2.99

3.12

3.24

3.35

 

BTUH

13,700

15,750

17,825

19,900

21,975

24,050

26,100

28,200

30,250

34,725

39,200

42,800

45,850

48,875

51,900

WH421

WATTS

2,975

3,075

3,175

3,275

3,350

3,450

3,550

3,650

3,750

3,825

3,925

4,025

4,100

4,200

4,300

 

COP

1.34

1.50

1.64

1.78

1.92

2.08

2.15

2.26

2.36

2.65

2.92

3.11

3.27

3.41

3.53

 

BTUH

17,950

19,900

21,875

23,850

26,200

28,500

29,750

31,700

33,675

38,800

43,900

47,950

51,175

54,400

57,650

WH483

WATTS

3,450

3,550

3,625

3,700

3,800

3,900

3,975

4,075

4,150

4,250

4,300

4,425

4,500

4,600

4,700

 

COP

1.52

1.64

1.76

1.88

2.00

2.15

2.20

2.27

2.37

2.67

2.89

3.17

3.33

3.46

3.59

 

BTUH

24,775

26,500

28,300

30,100

31,900

33,650

35,450

37,200

39,000

46,900

54,800

60,500

64,700

68,900

73,000

WH602

WATTS

4,100

4,225

4,325

4,425

4,525

4,625

4,750

4,850

4,950

5,050

5,150

5,250

5,375

5,475

5,575

 

COP

1.65

1.72

1.79

1.83

1.87

2.05

2.19

2.24

2.30

2.71

2.90

3.26

3.53

3.69

3.83

*70oF DB indoor return air at rated CFM includes defrost operation below 45o.

Form No.

S3210-206

Supersedes

S3210-106

Page

11 of 12

Page 11
Image 11
Bard WH Series manual Rated +10, Model 10o 15o 20o 25o 30o 35o 40o 45o 50o 55o 60o 65o, Watts, COP Btuh

WH Series specifications

The Bard WH Series is a distinguished line of high-efficiency heating systems designed for commercial and industrial applications. Renowned for their performance and reliability, these heating units play a crucial role in providing optimal comfort and climate control in various settings, such as schools, offices, and manufacturing facilities.

One of the standout features of the Bard WH Series is its efficient heat exchange technology. The series employs advanced heat exchanger designs that maximize thermal efficiency, ensuring that the units generate more heat with less energy consumption. This feature not only reduces overall energy costs but also minimizes carbon emissions, making it an environmentally friendly choice.

The WH Series incorporates a robust and durable construction. It is built to withstand demanding conditions often found in commercial environments. The cabinet is constructed from heavy-gauge steel which is coated with a corrosion-resistant finish, providing longevity and protection against harsh weather conditions. This rugged design ensures that the units continue to operate effectively even under heavy use.

Bard has integrated advanced control technologies into the WH Series, offering users precise temperature management. The intelligent control systems provide options for programmable settings, enabling users to customize heating schedules according to their needs. This capability not only enhances user comfort but also promotes energy savings by allowing the system to operate only when needed.

Another key characteristic of the Bard WH Series is its low noise operation. This is particularly important in settings where noise can be disruptive, such as schools or office environments. The series features quiet blowers and sound-attenuating designs that ensure minimal operational noise, allowing for a conducive environment even during peak heating periods.

The WH Series also includes a range of models to meet diverse heating requirements. With different capacity options and configurations available, users can select the unit that best fits their specific space and heating demands. Additionally, the units can be easily integrated with existing HVAC systems, providing flexibility and convenience for installations.

In conclusion, the Bard WH Series is engineered to deliver superior heating performance while emphasizing efficiency, durability, and user comfort. Its combination of cutting-edge technology, robust construction, and design considerations makes it a preferred choice for those seeking reliable heating solutions in commercial and industrial settings.