Bard WH Series manual Heat Pump Wall-Mount Model Nomenclature, Ventilation Options

Models: WH Series

1 12
Download 12 pages 722 b
Page 12
Image 12

Heat Pump Wall-Mount Model Nomenclature

 

 

 

 

WH

36

1

-

A

10

 

 

X

X

X

X

 

MODEL NUMBER l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

 

 

 

 

 

 

 

 

 

 

 

KW ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

- 1½ Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTS & PHASE

 

 

 

 

 

 

 

 

 

24

- 2 Ton

 

REVISION l

 

 

 

 

 

 

 

 

 

 

COLOR OPTIONS

 

 

 

 

 

 

 

A - 230/208/60/1

 

 

 

 

30

- 2½ Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X - Beige (Standard)

 

 

 

 

 

 

 

 

 

 

 

B - 230/208/60/3

 

 

 

 

36

- 3 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - White

 

 

 

 

 

 

 

 

 

 

 

 

 

C - 460/60/3

 

 

 

 

 

 

42

- 3½ Ton

 

SPECIALTY PRODUCTS 2

 

 

 

 

 

2

- Mesa Tan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

- 4 Ton

 

(Non-Standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

- Buckeye Gray

60

- 5 Ton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

- Desert Brown

 

 

 

 

 

 

 

VENTILATION OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

- Dark Bronze

 

 

 

 

 

 

 

 

 

(See Table Below)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XB

CONTROL MODULES

(See Chart Below)

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

FILTER OPTIONS

X - 1 inch Throwaway (Standard)

W - 1 inch Washable

P - 2 inch Pleated

1 For 0KW and circuit breakers (230/208 volt) or toggle disconnects (460 volt) applications, insert 0Z in the KW field of the model number. 2 Insert “D” for dehumidification with hot gas reheat. Reference Form F1743 for complete details.

OUTLET OPTIONS X - Front (Standard) T - Top (on WH30 and

WH36 Models)

Ventilation Options

MODELS

WH184, WH242

WH301, WH361

WH421, WH483, WH602

Description

Factory Installed

Field Installed

Factory Installed

Field Installed

Factory Installed

Field Installed

Code No.

Part No.

Code No.

Part No.

Code No.

Part No.

 

Barometric Fresh Air Damper - Standard

X

BFAD-2

X

BFAD-3

X

BFAD-5

 

 

 

 

 

 

 

Blank-Off Plate

B

BOP-2

B

BOP-3

B

BOP-5

 

 

 

 

 

 

 

Motorized Fresh Air Damper

M

MFAD-2

M

MFAD-3

M

MFAD-5

 

 

 

 

 

 

 

Commercial Ventilator - Spring Return w/Exhaust

V

CRV-2

V

CRVS-3

V

CRVS-5

 

 

 

 

 

 

 

Commercial Ventilator - Power Return w/Exhaust

---

---

P

CRVP-3

P

CRVP-5

 

 

 

 

 

 

 

Economizer (Internal) - Fully Modulating

E

EIFM-2B

E

EIFM-3C

E

EIFM-5C

 

 

 

 

 

 

 

Energy Recovery Ventilator - 230 Volt

R

WERV-A2B

R

WERV-A3C 1

R

WERV-A5C 1

 

 

 

 

 

 

 

Energy Recovery Ventilator - 460 Volt

R

WERV-C2B

R

WERV-C3C 1

R

WERV-C5C 1

 

 

 

 

 

 

 

1 Intake and exhaust can be independently adjusted.

Heat Pump Control Modules

Factory Installed

Field Installed

 

Description

 

 

Code

Part

Low Pressure

Low Ambient Control

 

Start Kit ￿

Outdoor

Number

Number

 

Control 1

and Relay ￿

 

Thermostat ￿

 

 

 

 

B

CMH-3

￿

 

 

 

 

 

 

 

 

 

 

 

E

CMH-7

 

￿

 

 

 

 

 

 

 

 

 

 

O

CMH-9

￿

￿

 

 

 

 

 

 

 

 

 

 

Q

CMH-14

 

 

 

 

￿

 

 

 

 

 

 

 

R

- - -

￿

￿

 

 

￿

 

 

 

 

 

 

 

S

- - -

￿

￿

 

￿

 

 

 

 

 

 

 

 

T

- - -

￿

￿

 

￿

￿

 

 

 

 

 

 

 

P

CMC-15 ￿

 

 

 

￿

 

 

 

 

 

 

 

 

U

- - -

￿

 

 

 

￿

 

 

 

 

 

 

 

1The low pressure control is auto reset. It includes a lock-out feature and is resettable from the wall thermostat. All low pressure controls use a timed bypass circuit

to prevent nuisance tripping during low temperature start-up.

2The low ambient control includes an 8201-008 (fan relay) and permits cooling operation down to 0°F.

3For WH242-A, WH301-A, WH361-A and WH421-A models. The CMC-15 can be used with any control module combination. NOTE: The compressor anti-cycle relay is standard on all heat pump models.

4The outdoor thermostat is adjustable from 0°F to 50°F. It is suitable for use as a compressor cut-off thermostat.

BARD MANUFACTURING CO. BRYAN, OHIO 43506 www.bardhvac.com

Due to our continuous product improvement policy, all specifications subject to change without notice.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.

Form No.

S3210

February, 2006

Supersedes S3210-106

Form No.

S3210-206

Supersedes

S3210-106

Page

12 of 12

Page 12
Image 12
Bard WH Series manual Heat Pump Wall-Mount Model Nomenclature, Ventilation Options, Heat Pump Control Modules

WH Series specifications

The Bard WH Series is a distinguished line of high-efficiency heating systems designed for commercial and industrial applications. Renowned for their performance and reliability, these heating units play a crucial role in providing optimal comfort and climate control in various settings, such as schools, offices, and manufacturing facilities.

One of the standout features of the Bard WH Series is its efficient heat exchange technology. The series employs advanced heat exchanger designs that maximize thermal efficiency, ensuring that the units generate more heat with less energy consumption. This feature not only reduces overall energy costs but also minimizes carbon emissions, making it an environmentally friendly choice.

The WH Series incorporates a robust and durable construction. It is built to withstand demanding conditions often found in commercial environments. The cabinet is constructed from heavy-gauge steel which is coated with a corrosion-resistant finish, providing longevity and protection against harsh weather conditions. This rugged design ensures that the units continue to operate effectively even under heavy use.

Bard has integrated advanced control technologies into the WH Series, offering users precise temperature management. The intelligent control systems provide options for programmable settings, enabling users to customize heating schedules according to their needs. This capability not only enhances user comfort but also promotes energy savings by allowing the system to operate only when needed.

Another key characteristic of the Bard WH Series is its low noise operation. This is particularly important in settings where noise can be disruptive, such as schools or office environments. The series features quiet blowers and sound-attenuating designs that ensure minimal operational noise, allowing for a conducive environment even during peak heating periods.

The WH Series also includes a range of models to meet diverse heating requirements. With different capacity options and configurations available, users can select the unit that best fits their specific space and heating demands. Additionally, the units can be easily integrated with existing HVAC systems, providing flexibility and convenience for installations.

In conclusion, the Bard WH Series is engineered to deliver superior heating performance while emphasizing efficiency, durability, and user comfort. Its combination of cutting-edge technology, robust construction, and design considerations makes it a preferred choice for those seeking reliable heating solutions in commercial and industrial settings.