oUnscrew the injector and replace it with the stipulated injector for the new gas supply (see table below).

Burner

Types

Pressure

Injector

Gas

 

Power

 

of gas

(mbar)

Marking

consumption

(kW)

 

 

 

(1/100

g/h

 

l/h

Max.

Min.

 

 

 

mm)

 

 

 

 

 

Auxiliary

Natural

20

72

-

 

95

1.00

0.48

 

(G20)

 

 

 

 

 

 

 

 

Butane

30

50

73

 

-

 

 

 

(G30)

 

 

 

 

 

 

 

 

Propane

37

50

71

 

-

 

 

 

(G31)

 

 

 

 

 

 

 

Semi-

Natural

20

97

-

 

167

1.75

0.60

rapid

(G20)

 

 

 

 

 

 

 

 

Butane

30

65

127

 

-

 

 

 

(G30)

 

 

 

 

 

 

 

 

Propane

37

65

125

 

-

 

 

 

(G31)

 

 

 

 

 

 

 

Rapid

Natural

20

115

-

 

286

3.00

1.05

 

(G20)

 

 

 

 

 

 

 

 

Butane

30

85

254

 

-

 

 

 

(G30)

 

 

 

 

 

 

 

 

Propane

37

85

250

 

-

 

 

 

(G31)

 

 

 

 

 

 

 

Wok

Natural

20

135

-

 

286

3.50

1.80

 

(G20)

 

 

 

 

 

 

 

 

Butane

30

95

218

 

-

 

 

 

(G30)

 

 

 

 

 

 

 

 

Propane

37

95

214

 

-

 

 

 

(G31)

 

 

 

 

 

 

 

oReassemble all the burners carefully; in particular you should make sure that the flame spreader is correctly placed on the burner.

IMPORTANT: After changing the injectors YOU MUST follow the minimum flow adjustment section on the next page.

31

Page 31
Image 31
Baumatic BC391.3TCSS manual Max Min Auxiliary