Baxi Potterton 47-393-42, 47-393-40 Site Requirements, Location, At Least 1.5 7.2 Clearances Figs

Models: 47-393-40 47-393-41 47-393-39 47-393-42

1 64
Download 64 pages 59.33 Kb
Page 15
Image 15

7.0 Site Requirements

5mm Min

 

 

 

 

450mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5mm Min

200mm Min

(300mm Min if

using 80/125mm

flueing system)

780mm

7.1Location

1.The boiler may be fitted to any suitable wall with the flue passing through an outside wall or roof and discharging to atmosphere in a position permitting satisfactory removal of combustion products and providing an adequate air supply. The boiler should be fitted within the building unless otherwise protected by a suitable enclosure i.e. garage or outhouse. (The boiler may be fitted inside a cupboard-see Section 7.3).

2.If the boiler is sited in an unheated enclosure then it is recommended to leave the ON/OFF Selector Switch in the domestic hot water and central heating position to give frost protection.

Fig. 8

450mm Min

For Servicing

Purposes

5mm Min

In Operation

Fig. 9

 

 

 

 

3. If the boiler is fitted in a room containing a bath or shower

 

 

 

 

reference must be made to the relevant requirements.

 

 

 

 

In GB this is the current I.E.E. Wiring Regulations and Building

 

 

 

 

Regulations.

 

 

 

 

In IE reference should be made to the current edition of I.S.

 

 

 

 

813 “Domestic Gas Installations” and the current ETCI rules.

 

 

 

 

4. If the boiler is to be fitted into a building of timber frame

 

 

 

 

construction then reference must be made to the current

 

 

 

 

 

 

 

 

edition of Institute of Gas Engineers Publication IGE/UP/7

 

 

 

 

 

150mm

Min*

(Gas Installations in Timber Framed Housing).

 

 

 

 

 

 

 

 

 

 

*This is the MINIMUM recommended dimension. Greater clearance will aid installation and maintenance.

At Least 1.5° 7.2 Clearances (Figs. 8 & 9)

1. A flat vertical area is required for the installation of the boiler.

2. These dimensions include the necessary clearances around the boiler for case removal, spanner access and air movement. Additional clearances may be required for the passage of pipes around local obstructions such as joists running parallel to the front face of the boiler.

© Baxi Heating UK Ltd 2012

15

Page 15
Image 15
Baxi Potterton 47-393-42, 47-393-40, 47-393-39, 47-393-41 manual Site Requirements, Location, At Least 1.5 7.2 Clearances Figs

47-393-40, 47-393-41, 47-393-39, 47-393-42 specifications

The Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 are models of high-efficiency gas boilers designed for residential heating. These models are well-known for their reliability, advanced technology, and user-friendly features, making them a popular choice among homeowners looking to improve their heating systems.

One of the standout features of these models is their energy efficiency. Each unit is engineered to comply with stringent energy-saving regulations, significantly reducing utility bills while maintaining optimal heating performance. They are rated with impressive efficiency ratings, which can lead to long-term savings and a reduced carbon footprint.

The Baxi Potterton range employs a heat exchanger system designed to maximize heat transfer and minimize energy waste. This sophisticated technology ensures that the boiler operates at peak efficiency, providing ample heating for homes even in the coldest months. The use of a durable, high-quality heat exchanger material contributes to the longevity of the unit, reducing the need for frequent repairs or replacements.

Ease of use is another hallmark of the 47-393 series. With an intuitive digital display, users can effortlessly monitor and adjust settings as required. The controls are straightforward, allowing for quick temperature adjustments, system diagnostics, and alerts, creating a hassle-free experience for homeowners.

Safety features are inherent in these models, including built-in safeguards against overheating and pressure fluctuations. The automatic shut-off mechanism ensures that the boiler operates within safe parameters, providing peace of mind to users.

Furthermore, maintenance is simplified with the easy access design. The accessible components make it straightforward for service technicians to perform routine checks and repairs. Regular maintenance is essential for sustaining high performance and extending the lifespan of the boiler.

In conclusion, the Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 models represent a blend of efficiency, safety, and convenience. Their advanced technologies and features not only enhance the user experience but also contribute to more sustainable heating solutions for homes. Investing in one of these advanced boilers ensures reliable performance, lower energy costs, and a commitment to environmental responsibility.