18.0 Fault Finding

Refer to Section 16.0 “Illustrated Wiring Diagram” for position of terminals and components

Central Heating - Follow operational sequence

Turn selector switch to

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The display illuminates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error 110 flashing

 

 

 

 

 

YES

Error 130 flashing

 

 

 

 

 

Error 133 flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Error 20, 28 or 50 flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Error 119 flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn Central Heating

 

 

 

 

 

NO

thermostat to Maximum.

Pump runs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Error 125 or 193 flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

3-way valve is open to Central

Heating circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

Fan runs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan runs at correct speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spark at ignition electrodes for

NO

up to 5 seconds and for 3

 

 

 

attempts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to section ‘A’

 

Turn the selector switch to

YES

 

reset position for 5 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to section ‘E’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to section ‘C’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure all controls (and

 

YES

 

integral clock if fitted) are

 

 

calling for heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ensure that primary

 

 

 

 

 

circulation is OK & that

 

 

 

 

 

there is no blockage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to section ‘K’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error 160 flashing

 

 

 

 

 

Go to section ‘D’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error 160 flashing

 

 

 

 

 

Go to section ‘L’

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

Error 133 flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to section ‘F’

 

 

 

 

 

 

 

 

 

 

 

If the error 110 is still flashing.

Go to section ‘J’

Ensure controls are set to

demand and verify the

contacts are closed

Go to section ‘B’

Go to section ‘H’

Turn the selector switch to

reset

 

YES

Burner lights

 

 

 

YES

NO

Burner output modulates to maintain the temperature set

Burner does not stay alights

after 5 seconds

Check the Central Heating

NTC sensor

Go to section ‘E’

Error 130 flashing

Go to section ‘M’

YES

Error 133 flashing Go to section ‘I’

YES

Burner goes out

YES

Fan stops after 10 seconds

YES

Pump continues to run for 3

minutes

(room thermostat open)

YES

Operation sequence

successful

© Baxi Heating UK Ltd 2012

55

Page 55
Image 55
Baxi Potterton 47-393-42 Error 133 flashing, Pump runs, Heating circuit, Go to section ‘A’ Turn the selector switch to

47-393-40, 47-393-41, 47-393-39, 47-393-42 specifications

The Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 are models of high-efficiency gas boilers designed for residential heating. These models are well-known for their reliability, advanced technology, and user-friendly features, making them a popular choice among homeowners looking to improve their heating systems.

One of the standout features of these models is their energy efficiency. Each unit is engineered to comply with stringent energy-saving regulations, significantly reducing utility bills while maintaining optimal heating performance. They are rated with impressive efficiency ratings, which can lead to long-term savings and a reduced carbon footprint.

The Baxi Potterton range employs a heat exchanger system designed to maximize heat transfer and minimize energy waste. This sophisticated technology ensures that the boiler operates at peak efficiency, providing ample heating for homes even in the coldest months. The use of a durable, high-quality heat exchanger material contributes to the longevity of the unit, reducing the need for frequent repairs or replacements.

Ease of use is another hallmark of the 47-393 series. With an intuitive digital display, users can effortlessly monitor and adjust settings as required. The controls are straightforward, allowing for quick temperature adjustments, system diagnostics, and alerts, creating a hassle-free experience for homeowners.

Safety features are inherent in these models, including built-in safeguards against overheating and pressure fluctuations. The automatic shut-off mechanism ensures that the boiler operates within safe parameters, providing peace of mind to users.

Furthermore, maintenance is simplified with the easy access design. The accessible components make it straightforward for service technicians to perform routine checks and repairs. Regular maintenance is essential for sustaining high performance and extending the lifespan of the boiler.

In conclusion, the Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 models represent a blend of efficiency, safety, and convenience. Their advanced technologies and features not only enhance the user experience but also contribute to more sustainable heating solutions for homes. Investing in one of these advanced boilers ensures reliable performance, lower energy costs, and a commitment to environmental responsibility.