SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

Shut off all power going to the header before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.

Ensure compliance with all applicable safety standards upon completion of installation

MECHANICAL

INSTALLATION -

OPENING THE

SENSOR

From behind, before installation

From the front, after installation

MECHANICAL

INSTALLATION -

PREPARATION

FOR MOUNTING

THE SENSOR

Paste the template at desired location. Drill as instructed.

Insert screws but do not screw them fully in.

If possible, pass the cable where it is supposed to go through.

If you don't want to drill your profile for the cable, you can cut the wire opening footprint as shown in the picture.

ELECTRICAL INSTALLATION - CABLING & CONNECTION

Run the cable through the wire passage hole just below PCB.

Position the sensor and tighten the two screws. Make sure you leave enough cable to reach the terminal block.

12-24 V AC/DC COM NO NC