Beckett 7505 warranty Product Description, Features & Benefits, Advanced Burner Control

Models: 7505

1 2
Download 2 pages 22.6 Kb
Page 1
Image 1
Advanced Burner Control

7505 PARTS & ACCESSORIES

Advanced Burner Control

Product Description

The Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time.

Features & Benefits

Thermostat and boiler control compatible

Customizable pre-time and post-time

Three status lights for system monitoring and diagnostics

Welded relay protection with redundant motor relays

Limited reset and limited recycle

Sleek, modern design

Cad cell resistance indicator

Technician Pump Prime mode

5-Year Warranty

Two communication ports for adding alarm contacts, programming display, and/or future wireless communications

Add a GeniSys Display and GeniSys Lockout Alarm

to fully utilize the features of the GeniSys advanced burner control.

The GeniSys Display (Pt. No. 52067) allows a technician to monitor and program the primary control variables. The display shows current burner status, control timings, and burner cycle history. The display’s programming mode allows a technician to customize both the pre-time and post-time settings and a lockout service message.

32 character backlit alphanumeric display

Sealed pushbutton keypad

Low voltage operation

Continuous real-time cycle monitoring

Continuous cad cell resistance reading

Continuous AC line voltage read-out

Real-time error notification

Customizable pre-time (valve-on delay) & post-time (motor off delay)

15 cycle history monitoring

Five Year Warranty

Customizable lockout service message

The GeniSys Lockout Alarm (Pt. No. 52040) functions as the interface between the primary control and an existing alarm panel or any alarm mechanism requiring contact closure in the event of a soft or hard lockout of the GeniSys Control.

To learn more, see www.beckettcorp.com or ask for literature pt. nos. 61669 & 61687