Beckett ADC manual Prepare Before Installing Specifications, Owner’s Responsibility, Do Not Use Gas

Models: ADC

1 16
Download 16 pages 53.34 Kb
Page 3
Image 3
Section: Prepare Before Installing

Section: Prepare Before Installing

Prepare Before Installing Specifications

Owner’s Responsibility

Incorrect installation, adjustment, and use of this burner could result in severe personal injury, death, or substantial property damage from fire, carbon monoxide poisoning, soot or explosion.

Contact a professional, qualified service agency for the installation, adjustment and service of your oil heating system. This work requires technical training, trade experience, licensing or certification in some states and the proper use of special combustion test instruments.

Please carefully read and comply with the following instructions:

yNever store or use gasoline or other flammable liquids or vapors near this burner or appliance.

yNever attempt to burn garbage or refuse in this appliance.

yNever attempt to light the burner/appliance by throwing burning material into the appliance.

yNever attempt to burn any fuel not specified and approved for use in this burner.

yNever restrict the air inlet openings to the burner or the combustion air ventilation openings in the room.

Impaired Burner Performance

and Fire Hazard.

Do NOT operate the burner beyond specifications outlined in the table to the right.

yFor applications beyond these limits, consult Beckett Technical Service at 1-800-645-2876.

yNOTE: Some packaged appliances with burners may be agency listed as a unit to operate beyond these limits. Consult the appliance manufacturer’s specifications and agency approvals for verification.

Capacity

‘F’ Head

 

Firing Rate: 0.75 - 2.50 GPH

 

Input: 105,000 - 350,000 Btu/h

 

 

Fuels

USA: No. 1 or No. 2 diesel fuel or kerosene;

 

No.1 or No. 2 heating oil (ASTM D396)

 

 

DO NOT USE GAS-

 

 

 

OLINE, CRANKCASE OIL, OR ANY

 

OIL CONTAINING GASOLINE.

 

 

 

Electrical

Power Supply: 13.5 Vdc

 

Operating Load

 

w/ igniter on: 15 Amps

 

w/ igniter off: 8 - 10 Amps

 

Motor: 13.5Vdc, 1/6 hp, 3450 RPM, 10

 

Amps (max.) NEMA “M” Flange, rotation

 

CCW when facing shaft end.

 

Ignition Secondary: 20KVpk 25mA

 

Interrupted duty OR optional continuous

 

duty.

 

 

 

Pump

Outlet pressure: Note 1

 

 

 

Dimensions

Height (maximum): 11 ½ inches

 

Width (maximum): 14 3/8 inches

 

Depth (chassis only): 6 9/16 inches

 

Air tube diameter: 4 inches

 

 

 

Ambient

+32° F. (0° C.) Minimum

Operating

+115° F. (+46° C.) Maximum

Temperature

(See Warning on Impaired Burner

 

Performance and Fire Hazard.)

Note 1. See equipment manufacturer’s burner specifications for recommended outlet pressure. Pressure is 100 psig unless otherwise noted.

Notice Special Requirements

If you discover damage to the burner or controls during unpacking, notify

the carrier at once and file the appropriate claim.

When contacting Beckett for service information — Please record the burner serial number (and have available when calling or

writing). You will find the serial number on the silver label located on the left rear of the burner. See Figure 1.

12 Vdc ADC Burner Manual

3

Page 3
Image 3
Beckett ADC Prepare Before Installing Specifications, Owner’s Responsibility, Notice Special Requirements, Do Not Use Gas