Beckett ADC manual Section Burner Wiring

Models: ADC

1 16
Download 16 pages 53.34 Kb
Page 8
Image 8
Section: Burner Wiring

Section: Burner Wiring

Figure 6A. Typical Wiring For Constant Duty Ignition - With No Primary Control

SAFETY AND

LIMIT CONTROLS

50A

30A

FUSE

FUSE

ORANGE

MOTOR

OPERATING

CONTROLS

10A FUSE

BLUE WITH

SOLID

VIOLET(+)

WHITE STRIPE

WHITE

 

YELLOW

CAPPEDIGNITER VALVE

(NOT USED)

BLACK

BLACK

WHITE(-)

Manual background GND

FROM 12 - 13.5 Vdc

POWER SUPPLY

Notes:

1.Wires are to be sized to prevent a voltage drop between battery and burner with burner running at full load.

2.Motor runs continuously in normal confi guration.

3.Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

SK10087

Figure 6B. Typical Wiring For Interrupted Ignition - With No Primary Control

SAFETY AND

LIMIT CONTROLS

50A

30A

FUSE

FUSE

OPERATING CONTROLS

10A FUSE

ORANGE

VIOLET(+)

SOLID

BLUE W/

WHITE

WHITE STRIPE

 

 

MOTOR

VALVE

IGNITER

YELLOW

CAD

CELL

 

 

 

YELLOW

 

 

 

 

BLACK

WHITE(-)

BLACK

Manual background GND

FROM 12 - 13.5 Vdc

POWER SUPPLY

Notes:

1.Wires aret to be sized to prevent a voltage drop between battery and burner with burner running at full load.

2.Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

SK10088

8

Page 8
Image 8
Beckett ADC manual Section Burner Wiring