Section: Mount the Burner

Mount Air Tube to Burner

○ Slide the secondary adjusting plate (item f)

Remove the rear access door from the back of the

completely to the left on the indicator adjusting plate

(item e). Finger-tighten acorn nut (item c) to secure

burner for improved access to the interior.

the two plates together. Slide both plates completely

Attach the air tube to the burner with the bolts and acorn

to the left on the primary adjusting plate (item g) and

nuts provided. The acorn nuts must go on the outside of

finger-tighten acorn nut (item d).

the burner, with the bolts inserted from the inside.

○ Slide the completed adjusting plate assembly

 

 

over the nozzle line end. Move the plate assembly

Install Nozzle

and the nozzle line so the plate assembly fits into

See Figure 5. Install the oil nozzle in the nozzle adapter.

position as shown in Figure 6.

○ Install the spline nut (item b) on the end of the

Use a 3/4” open-end wrench to steady the nozzle

nozzle line, leaving the nut loosely placed so the

adapter and a 5/8” open-end wrench to turn the nozzle.

plates can be moved.

Tighten securely but do not overtighten.

○ Connect the high-voltage leads from the ignition

 

 

transformer to the electrodes.

Check Electrode Settings

Maintain Electrode

Specifications

Failure to properly maintain these specifications could cause ignition malfunction, puff-back of hot gases, heavy smoke, asphyxiation, explosion and fire hazards.

Check, and adjust if necessary, the critical dimensions P, Q, R and S shown in Figure 5. Verify that the oil tube assembly and electrodes are in good condition, with no cracks or damage.

Figure 5 – Nozzle and Nozzle Line Assembly

Legend (Figure 5)

PNozzle centerline to electrode tip - 1/4”

QNozzle to head - 1/4”

RNozzle face to electrode tip - 1/8”

SElectrode spacing - 3/32”

Install Nozzle Line Assembly

Insert the nozzle line assembly into the burner air tube as in Figure 6.

See Figures 6 and 7. Assemble the adjusting plate assembly per the instructions in the assembly packet.

Figure 6 – Nozzle Line Assembly in Burner

z (Measured from the flat front surface of the head to the end of the air tube, as shown).

a

Measure dimension Z from the flat surface between (not on) the raised fins.

Z = 1-3/4” ± 1/16”

Legend (Figures 6 & 7)

aAdjusting plate assembly

bSpline nut for securing nozzle line

cBottom acorn nut

dTop acorn nut (for setting dim. Z only)

eIndicator adjusting plate

fSecondary adjusting plate g Primary adjusting plate

8

Page 8
Image 8
Beckett CF1400 manual Mount Air Tube to Burner, Install Nozzle, Check Electrode Settings Maintain Electrode Specifications

CF1400 specifications

Beckett has long been a household name in the heating and oil burner industry, renowned for producing equipment that excels in efficiency, reliability, and innovation. Among its impressive range of products, the CF1400 and CF2300 models stand out as exceptional offerings in the category of oil burners.

The Beckett CF1400 is designed for residential applications, delivering a robust performance that satisfies heating needs while minimizing energy consumption. This model is equipped with advanced technology that ensures precise fuel atomization, which translates into cleaner combustion and lower emissions. With adjustable combustion settings, users can optimize the burner for different home heating systems, ensuring peak performance regardless of the conditions.

In contrast, the CF2300 model is engineered for larger residential or light commercial setups. This powerhouse of a burner leverages enhanced fuel delivery systems and cutting-edge control features that allow for efficient operation and maintenance. Its design incorporates a heat exchanger that maximizes heat transfer, resulting in improved energy efficiency. Beckett’s commitment to quality is evident in its use of durable materials, ensuring that these units offer longevity and consistent performance over time.

Both models share several key technologies and characteristics. They are compatible with various heating oil types and can accommodate different fuel tank arrangements. The burners feature adjustable air settings, allowing for easy tuning to achieve optimal combustion performance. The CF1400 and CF2300 are also characterized by quiet operation, ensuring homeowners can enjoy a warm environment without disruptive noise levels.

Safety is paramount in the design of the CF series. Each unit comes equipped with safety controls that prevent overheating and other potential hazards, providing peace of mind to users. Furthermore, installation is user-friendly, and regular maintenance is simplified, reducing service costs and extending the lifespan of the burners.

The Beckett CF1400 and CF2300 models exemplify the brand's dedication to technological advancement and user-centric design. With their combination of efficiency, reliability, and cutting-edge features, these oil burners continue to be preferred choices for homeowners looking to improve their heating systems. Whether for residential or light commercial use, these models provide dependable heating solutions that align with modern energy standards.