Behringer CX3400 manual INPUT connector. Input signal connector

Models: CX3400

1 22
Download 22 pages 35.03 Kb
Page 13
Image 13
Manual background

6

7

8

9

10

11

15

19

24

25

26

27

28

29

30

31

LOW OUTPUT control. Controls the output level of the Low band from +6 to -6 dB. LOW PHASE INVERT button. This button reverses the polarity of the Low output. LOW MUTE button. Mutes the Low band.

LOW-MID OUTPUT control. Controls the output level of the Low-Mid band from +6 to -6 dB. LOW-MID PHASE INVERT button. This button reverses the polarity of the Low-Mid output. LOW-MID MUTE button. Mutes the Low-Mid band.

CD HORN button. This button provides a special form of frequency correction in the High band for constant-directivity horns.

HIGH-MID/HIGH XOVER FREQ. control. This control governs the crossover frequency between the High-Mid and High bands.

HIGH-MID OUTPUT control. Controls the output level of the High-Mid band from +6 to-6 dB. HIGH-MID PHASE INVERT button. This button reverses the polarity of the High-Mid output. HIGH-MID MUTE button. Mutes the High-Mid band.

HIGH OUTPUT control. Controls the output level of the High band from +6 to -6 dB. HIGH PHASE INVERT button. This button reverses the polarity of the High output. HIGH MUTE button. Mutes the High band.

THRESHOLD control. This control determines the limiter threshold.

LIMITER button. This button activates all limiters. Whenever the signal surpasses the limiter threshold, the LIM-LEDs above the Gain control light up, signaling that the CX3400 cuts back the output level.

3

4

8

Fig. 2.10: Active control elements on the rear panel of the SUPER-X PRO

HIGH OUTPUT connector. Output for the High band signal. HIGH-MID OUTPUT connector. Output for the High-Mid band signal.

MODE button. In mono 4-way mode, the right button must be pressed. Please observe the labels on the rear panel of the unit.

+Always switch off the entire system before you press this button, as it produces heavy interference noise that could damage your speakers and/or other equipment.

11

12

13

LOW-MID OUTPUT connector. Output for the Low-Mid band signal. LOW OUTPUT connector. Output for the Low band signal.

XOVER FREQ. button. This button serves to switch over the control range of the front-panel LOW/LOW-MID XOVER FREQ. control from 44 to 930 Hz or 440 Hz to 9.3 kHz.

+Always switch off the entire system before you press this button, as it produces heavy interference noise that could damage your speakers and/or other equipment.

14

INPUT connector. Input signal connector.

2. THE DESIGN CONCEPT

13

Page 13
Image 13
Behringer CX3400 manual INPUT connector. Input signal connector