![](/images/new-backgrounds/1210469/21046919x1.webp)
GOVERNOR GASKET
(SPECIAL GASKET,
SEE ASSEMBLY NOTE 6)GOVERNOR
SMALL
BODY
SPRING
LARGE
FIGURE 6 - BENDIX® AD-IS® AIR DRYER AND RESERVOIR SYSTEM DELIVERY CHECK VALVE
DELIVERY CHECK VALVE CLEANING PROCEDURE
(Note: This is only required if system pressure does not build after temporary bypass is completed.)
Refer to Figure 6 throughout the following procedures.
This procedure does not require removal of the Bendix®
1.Remove the line from the governor and mark for easy
2.Remove the bolts attaching the governor to the
3.Remove the governor from the air dryer. Be aware that a short puff of trapped air may vent when the governor is removed. Retain the governor gasket for
4.The spring/delivery check valve can now be removed.
5.Remove and retain the
CLEANING & INSPECTION
1.Use a suitable solvent to clean all metal parts, and use a cotton swab to clean the bore (Note: Do not use abrasives or tools to clean the bore: any scratches caused may necessitate replacing the Bendix®
2.Clean the
3.Inspect for physical damage to the bore and the check valve seat. If the bore is damaged (by scratches etc. that would prevent delivery check valve from seating), replace the
4.Inspect the delivery check valve,
5.Inspect all air line fittings for corrosion and replace as necessary.
10