Safety First

Safety First

General Information

Pump Location

General Safety

Do not allow pump, piping, or any other system component containing water to freeze. Freezing may damage system, leading to injury or flooding. Allowing pump or system components to freeze will void warranty.

Pump approved liquids only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see

General Information this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury:

warns about hazards that will cause Pump Location serious personal injury, death or major property damage if ignored.

General Safety warns about hazards that will or can cause serious personal injury, death or

major property damage if ignored.

READ AND FOLLOW warns about hazards that will or can cause minor personal injury or property

damage if ignored.

This is the safety alert symbol. When you see WARNING

Rotating parts. Can catch hands, feet, or clothing.

Stay clear of equipment and keep shields in place while pump is running.

Stop motor or engine before servicing pump.

Read owner’s manual before using equipment.

Electrical Safety

The label NOTICE indicates special instructions which are important but not related to hazards.

Carefully read and follow all safety instructions in this manual and on pump.

Keep safety labels in good condition. Replace missing or damaged safety labels.

LOCATION:

Locate the pump as near to the water source as practical. Make the suction pipe run short and straight with as few pipe fittings as possible to keep total friction loss to a minimum.

Install pump in a clean, dry and well drained location if possible and protect against moisture and adverse

WARNING

Hazardous voltage.

Can shock, burn, or

cause death.

Ground pump before

connecting to power

supply.

Wire motor for correct voltage. See “Electrical” section of this manual and motor nameplate.

Ground motor before connecting to power supply.

Meet National Electrical Code and local codes for all wiring.

Follow wiring instructions in this manual when connecting motor to power lines.

weather conditions. Pump should be located on a level, hard surface to prevent shifting or tipping. Locate to be readily accessible for inspection and maintenance.

Careful attention should be taken to assure that Net Positive Suction Head Available (NPSHA) exceeds Net Positive Suction Head Required (NPSHR) by the pump or reduced performance and severe pump damage may result.

Figure 1, Page 3, illustrates where these terms (NPSHA

/NPSHR) originate, and how to determine if the pumping conditions at which you want to operate meet the proper criteria. When in doubt, consult your nearest Berkeley Professional Dealer.

NOTE: If pump site is 1000 feet above sea level, sub- tract 1.2 feet from the NPSHA equation and an ad- ditional 1.2 feet for each additional 1000 feet of eleva- tion.

Page 2