Bertazzoni dimensions Models CB36600X, Models CB36500X, C3Y0..U7X2 or 5A, C3W0..U7X2 or 5A

Models: CB36600X CB36500X

1 12
Download 12 pages 20.92 Kb
Page 9
Image 9
Models CB36600X

Models CB36600X

[C3Y0..U7X(2 or 5)A]

 

 

 

 

Adapting to different types of gas

 

 

 

 

 

 

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By-pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary

Front R

0,92

 

NG

4”

3750

1098

900

264

Regulated

 

 

0,56

 

LP (Propane)

11”

3750

1098

900

264

0,29

Semi-Rapid

Rear L & C

1,17

 

NG

4”

6000

1759

1500

439

Regulated

 

Front C

0,73

 

LP (Propane)

11”

6300

1845

1500

439

0,36

Rapid

Rear R

1,55

 

NG

4”

10400

2046

2500

732

Regulated

 

 

0,98

 

LP (Propane)

11”

11400

3339

2500

732

0,47

Dual Burner

Front L Inner

0,80

 

NG

4”

2730

799

900

264

Regulated

 

0,50

 

LP (Propane)

11”

2900

8479

900

264

0,29

 

Front L Outer

N°2 x 1,30

NG

4”

15000

4394

4500

1319

Regulated

 

 

N°2 x 0,83

LP (Propane)

11”

16400

4804

4500

1319

0,65

Models CB36500X

[C3W0..U7X(2 or 5)A]

 

 

 

 

Adapting to different types of gas

 

 

 

 

 

 

 

Burner

Position

Injector

 

Gas

Pressure

Max Rate

Min Rate

By-pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

Diam. [mm]

Auxiliary

Front R

0,92

 

NG

4”

3750

1098

900

264

 

Regulated

 

 

0,56

 

LP (Propane)

11”

3750

1098

900

264

 

0,29

Semi-Rapid

Rear L and R

1,17

 

NG

4”

6000

1759

1500

439

 

Regulated

 

 

0,73

 

LP (Propane)

11”

6300

1845

1500

439

 

0,36

Rapid

Front L

1,55

 

NG

4”

10400

2046

2500

732

 

Regulated

 

 

0,98

 

LP (Propane)

11”

11400

3339

2500

732

 

0,47

Dual Burner

Centre Inner

0,80

 

NG

4”

2730

799

900

264

 

Regulated

 

0,50

 

LP (Propane)

11”

2900

8479

900

264

 

0,29

 

Centre Outer

N°2 x 1,30

 

NG

4”

15000

4394

4500

1319

 

Regulated

 

 

N°2 x 0,83

 

LP (Propane)

11”

16400

4804

4500

1319

 

0,65

CAUTION: save the orifices removed from the appliance for future use

Regulation of burners

Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:

1)Light the burner and set the knob to the MINIMUM position (small flame).

2)Remove the knob of the valve that is press fit on the rod of that valve.

3)The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum

4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always operates at maximum and therefore no minimum adjustment is required.