Room ventilation – Location and venting.

SECTION VIEW OF THE RIGHT ASSEMBLY

Room ventilation – Location and venting.

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the national standards in force.

ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force.

Conversion to different types of gas

Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. 5A. For LP Gas fit assembly described in fig. 5A.

-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig. 6) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below.

fig.6

TABLE A: Adapting to different types of gas

fig.7

Gas

 

NATURAL (A)

 

 

 

LP (E)

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Pressure

Inj. size

Input Rate

Simmer Rate

Pressure

Inj. size

Input Rate

Simmer Rate

By-pass size

Type

[i.w.c.]

1/100mm

[BTU/h]

[BTU/h]

[i.w.c.]

1/100mm

[BTU/h]

 

[BTU/h]

[1/100mm]

Auxiliary

 

0,90

3400

900

 

0,54

3400

 

900

29

 

 

 

 

 

 

 

 

 

 

 

Semi-Rapid

4"

1,18

6100

1500

11"

0,70

6100

 

1500

37

Triple Ring

 

1,65

11900

5300

 

1,02

12300

 

5300

73

 

 

 

 

 

 

 

 

 

 

 

CAUTION: save the orifices removed from the appliance for future use