PREPARE THE HOOD

NON - DUCTED CONFIGURATION, cont’d.

8.Carefully place the lower decorative flue into the recessed area of the range hood top. Fig. 7

9.Carefully slide the upper decorative flue down inside the lower flue.

Note: air vents must be up. Fig. 7

10.Secure the recirculation plenum to the

upper flue with (4) flat head screws. Fig. 10

PLENUM

4 FLAT

HEAD

SCREWS

UPPER

FLUE FIG.10

INSTALL THE HOOD

Note: at least two people will be required to mount the hood.

1.Raise the hood into its mounting position.

2.Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.

3.Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 11

4.Level the hood and secure with (2) mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 11

5.Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 12

6.Secure the flue with (2) mounting screws. Fig. 12

RECTANGULAR

CUTOUT

MOUNTING

SCREWS

MOUNTING

BRACKET

FIG.11

3.9x9.5mm

MOUNTING SCREWS

FIG.12

- 13 -