OPERATION

Controls

The hood is operated using the (4) pushbuttons located at eye-level, on the front edge of the hood.

The light switch turns the halogen lights on and off. Push the light switch once to turn the lights ON - push a second time to turn the lights ON to a brighter level - push a third time to turn the lights OFF.

LIGHT

SWITCH DISPLAY RESET SWITCH

TIMER

SWITCH BLOWER SWITCH

The timer switch turns the blower timer on and off. Push this switch once to turn the timer ON. With the blower timer turned ON, the speed that was selected will blink in the display; if the speed selection is changed the blower timer will remain ON; the blower will shut OFF after 10 minutes.

The display indicates:

-indicates the selected motor speed (from 1 to 4);

-indicates Timer On when the number blinks;

-indicates Filter Alarm when the central segments is on or blinking.

The blower switch turns the blower on and off. Push the switch once to turn the blower ON (turns on to last speed selected). Pushing the switch sequentially selects blower speeds from 1 to 4. To turn OFF the blower, push and hold the blower switch for approximately 2 seconds.

The reset switch resets the grease filter or charcoal filter alarm. The grease filter must be cleaned when the center segment of the display lights up continuously or blinks. The filter alarm will be seen in the DISPLAY for approximately 30 seconds after the blower is turned off. To reset the hour counter, keep the switch pressed for 2 seconds when the alarm can be seen in the DISPLAY.

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.