OPERATION
Controls
The hood is operated using the (5) push buttons located on the front edge of the hood.
The Light switch turns the halogen lights on and off. Push the light switch once to turn the lights ON - push a second time to turn the lights ON to a brighter level - push a third time to turn the lights OFF.
The Glass switch turns the glass light on. Push the glass switch once to turn the glass light ON - push a second time to turn the light OFF. Depress and hold the button to activate the automatic light sensor. When the LED Display indicates “A”, the glass light will automatically light when the room becomes dark. Push a second time to deactivate the sensor and turn the light off.
The Blower Off/Speed switch turns the blower off and changes blower speed to four different speed settings: high,
The Blower On/Speed switch turns the blower on to four different speed settings: Low,
The LED Display:
-Indicates blower speed selection from 1 (low speed) to 4 (high speed).
-Flashes the blower speed when the
-After 30 hours of operation, the center segment of the display blinks and remains lit, indicating that filters need to be cleaned.
-Indicates “A” when the Light Sensor is ON.
The Time Delay switch activates a delay off feature. When pushed, the blower will continue to operate at the current speed setting for
The Filter Alarm Reset switch is used to reset the
Glass Switch | Blower On/Speed | Time Delay/ | |
Filter Alarm Reset | |||
|
| ||
Light Switch | Blower Off/Speed | LED Display | |
|
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1)If blower is OFF - it turns blower ON to HIGH speed.
2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.
- 4 -