Bi-pin Florescent Lamp Installation / Verification
(Only Glass Door Models)
Prior to applying power to the unit, verify that all lamps are properly installed and fully engaged in the lamp holders.
Proper lamp engagement is achieved by rotating the lamp 90 degree from its insertion position until it snaps or clicks into place.
Visual verification can be made on units without safety shields by using the identification mark on the end of the bulb. Properly installed bulbs will have the mark centered between the halves of the lamp holder.
On units with shields, the identification mark cannot be seen. Physically verify that the lamp has been rotated and locked into place.
See pictures below.
Caution: Improperly installed lamps may cause damage to the lighting circuit.
Properly installed lamp with shield. | Improperly installed lamp with shield. |
Requires physical verification that lamp has | Note that pins have not achieved full 90… rotation |
been rotated and locked into place . |
|