Beyerdynamic SIR 320 SIR Infrared System, Trouble shooting, Fault, Possible reason, Action

Models: SIR 320

1 28
Download 28 pages 1.52 Kb
Page 22
Image 22
Trouble shooting

 

SIR 320

 

SIR Infrared System

 

 

 

 

 

 

Trouble shooting

 

 

 

 

 

 

 

 

 

Fault

Possible reason

Action

 

 

 

 

 

 

 

No sound at headphone

Headphone not connected

Plug in headphone

 

 

 

 

 

 

 

No sound at headphone

Receiver not switched-on

Push one button at the

 

 

 

 

navigation dial with

 

 

 

 

headphone connected

 

 

 

 

 

 

 

No sound at headphone

Display at the receiver not lighting

Insert new batteries and carry

 

 

 

after switching on.

out a hardware reset

 

 

 

Batteries not inserted, empty or

 

 

 

 

weak.

 

 

 

 

 

 

 

 

Receiver can not be

Undefined working order

Carry out a hardware reset

 

 

switched-on

 

 

 

 

 

 

 

 

 

After switching-on, the

Undefined working order

Carry out a hardware reset

 

 

back light is shining only,

 

 

 

 

no further keystroke is

 

 

 

 

possible

 

 

 

 

Receiver gets noise at the

No IR - reception

Switch on IR–transmitter

 

 

headphone only

 

 

 

 

 

 

 

 

 

Receiver gets noise at the

No IR - reception

Connect the radiators with

 

 

headphone only

 

active IR-transmitter

 

 

 

 

 

 

 

Receiver gets noise at the

No IR - reception

Change IR-channel to other

 

 

headphone only

 

position

 

 

 

 

 

 

 

Receiver gets noise at the

Selected IR-channel has no

Check IR-transmitter using

 

 

headphone only

transmission

correct adjustment

 

 

 

 

 

 

 

Receiver gets noise at the

Receiver is in Shift mode setting

Deactivate the Shift mode

 

 

headphone only

(instead displaying „00“ (OR-ch)

(See Service mode)

 

 

 

you will see „or“

 

 

 

No sound at headphone

Volume to low

Adjust volume (VOL up)

 

 

 

 

 

 

 

No sound at headphone

Wrong headphone used

Use the correct headphone

 

 

 

 

(see accessories)

 

 

 

 

 

 

 

Receiver switched off after

No reception signal

Check whether the IR-

 

 

approx. 15 sec.

 

transmitter and the radiators

 

 

 

 

are switched-on

 

 

 

 

 

 

 

Receiver switched off after

Reception channel will not be

Change channel setting

 

 

approx. 15 sec.

transferred from IR-transmitter

(channel up or down)

 

 

 

 

 

 

22

Copyright by beyerdynamic

Page 22
Image 22
Beyerdynamic SIR 320 operating instructions SIR Infrared System, Trouble shooting, Fault, Possible reason, Action