Billion Electric Company 7402 user manual Device Management, Embedded Web Server

Models: 7402

1 123
Download 123 pages 44.82 Kb
Page 115
Image 115
Device Management

Billion BIPAC-7402 / 7402W (Wireless) ADSL VPN Firewall Router with 3DES Accelerator

Device Management

The Device Management advanced configuration settings allow you to control your router’s security options and device monitoring features.

Embedded Web Server:

HTTP Port: This is the port number the router’s embedded web server (for web-based configuration) will use. The default value is the standard HTTP port, 80. Users may specify an alternative if, for example, they are running a web server on a PC within their LAN.

Management IP Address: You may specify an IP address allowed to logon and access the router’s web server. Setting the IP address to 0.0.0.0 will disable IP address restrictions, allowing users to login from any IP address.

Expire to auto-logout:Specify a time frame for the system to auto-logout the user’s

configuration session.

For Example: User A changes HTTP port number to 100, specifies their own IP address of 192.168.1.55, and sets the logout time to be 100 seconds. The router will only allow User A access from the IP address 192.168.1.55 to logon to the Web GUI by typing:

109

Chapter 4: Configuration

Page 115
Image 115
Billion Electric Company 7402 user manual Device Management, Embedded Web Server