FORCE BLOWER Owner’s Manual
SOUND
SOUND LEVEL 90 Db(a) at Operators Position
Sound tests were conducted in accordance with 2000/14/EC, as well as ISO 11094, and were performed on
Sound power level listed is the highest value for any model covered in this manual. Please refer to serial plate on the unit for the sound power level for your model.
General Conditions: | Sunny |
Temperature: | 79.7oF (26.5oC) |
Wind Speed: | 1.7 mph (2.8kph) |
Wind Direction: | South Southwest |
Humidity: | 31.2% |
Barometric Pressure: | 29.9Hg (101.25kpa) |
VIBRATION DATA
VIBRATION LEVEL 1.05g (10.30m/s2)
Vibration levels at the operator’s handles were measured in the vertical, lateral and longitudinal directions using calibrated vibration test equipment. Tests were performed on
General Conditions: | Sunny |
Temperature: | 86.5oF (30.3oC) |
Wind Speed: | 2.5 mph (4.1kph) |
Wind Direction: | South Southwest |
Humidity: | 56.4% |
Barometric Pressure: | 29.9Hg (101.25kpa) |
INTENDED USE
This machine is designed for cleaning outdoor surfaces, where the debris can be effectively blown into a consolidated area for convenient pickup and removal.
DO NOT OPERATE IF EXCESSIVE VIBRATION OCCURS. If excessive vibration occurs, shut engine off immediately and check for damaged or worn impeller, loose impeller bolt, loose impeller key, loose engine or debris stuck in fan or housing. To remove debris from impeller see the trouble shooting section on page 13. Note: See parts list for proper impeller bolt torque specifications.
Part No 440021 | 6 | Form No F071307B |