AIR FILTER COVER REMOVAL INSTRUCTION (HONDA)

Removing the air filter cover (for air filter change and throttle control installation)

1.Disconnect spark plug wire.

2.Remove the wingnut on the top of the air cleaner cover (fig. 1).

3.Remove the air filter cover by leaning the air cleaner cover towards the left side of the machine then remove (fig 2).

Figure 1

Figure 2

THROTTLE CONTROL CABLE INSTALLATION

Briggs & Stratton Engine

1.Remove clamp screw and cable clamp from front of engine (clamp must be on the left side on engine control lever. if clamp is on the right side, change to the left).

2.Insert "z" end of throttle cable into hole in engine lever, then secure cable with clamp screw and

cable clamp on the left side of the

Figure 3

engine control lever (DO not

 

tighten the screw) (Fig 3).

 

3. Route throttle cable behind

 

cover through the slots

 

provided(Fig 4).

Figure 4

 

4.Put throttle lever in the "fast" position at the handle.

6.Pull throttle control wire and casing back then tighten clamp screw. DO not over tighten (Fig 5).

Figure 5

Honda Engine

1.Remove air cleaner cover by removing wing nut at the top of cover.

2.Remove cable clamp and screw from engine control lever.

3.Attach "z" end of throttle cable through hole in engine control lever.

4.Replace cable clamp and screw but do not tighten.

5.Put throttle lever in "stop" position at the handle.

6.Pull throttle control wire and casing back then tighten clamp screw. DO not over tighten.

NOTE: If throttle control seems stiff, it may be necessary to

loosen the 10mm locknut on the engine control lever about 1/2 turn

7.Replace air cleaner and wing nut.