PERIODIC MAINTENANCE

Periodic maintenance should be performed at the following intervals:

Maintenance Operation

Every Use (daily)

Every 5 hrs (daily)

Every 10 Hrs

Every 25 Hrs

Every 50 Hrs

 

 

 

 

 

 

Inspect for loose, worn or damaged parts.

 

z

 

 

 

 

 

 

 

 

 

Clean Debris bag and check strap tightness

z

 

 

 

 

 

 

 

 

 

 

Check Tire pressure

z

 

 

z

 

 

 

 

 

 

 

Engine (See Engine Manual)

 

 

 

 

 

 

 

 

 

 

 

Check for excessive vibration

 

z

 

 

 

 

 

 

 

 

 

Check belt adjustment (pg. 15)

 

 

 

 

z

 

 

 

 

 

 

Grease wheel zerks

 

 

 

 

z

 

 

 

 

 

 

Lubricate Drive chain and oil control pivot

 

 

z

 

 

points

 

 

 

 

 

 

 

 

 

 

 

IMPELLER REMOVAL

1. Disconnect spark plug wire.

2. Disconnect remote control rod from nozzle gobbler door.

3. Elevate front of machine using stable support blocks between housing and ground so that front caster wheels are not touching ground.

4. Remove nozzle and caster wheel brackets from the housing.

5. Remove both the top and side belt guards between housing and transmission.

6. Loosen wire belt guide located on front face of engine on left side of unit between housing and engine.

7. Slide belt toward engine, out of belt groove in impeller hub drive pulley.

8. Remove impeller bolt and lock washer.

9. If impeller slides off freely, proceed to (step 12). (Do not drop impeller).

10.If impeller does not slide off crankshaft, place two crowbars between impeller and housing on opposite sides. Pry impelleraway from engine until it loosens. Using a penetrating oil can help loosen a stuck impeller.

11.If the impeller cannot be loosened, obtain a 1” (25.4mm) longer bolt of the same diameter and thread type as the impeller bolt. Invert engine and impeller and support engine above ground to prevent recoil damage. Thread longer bolt by hand into the crankshaft until bolt bottoms. Using a suitable gear or wheel puller against the bolt head and the impeller back-plate (near the blades), remove impeller from shaft.

12.Slide impeller off of crank shaft and remove impeller from housing.

13.Reinstall new impeller and all applicable spacers, new impeller bolt and lockwasher in reverse order of removal. (See the parts drawing on pages 16 and 17 for parts break-down and parts list on page 18 for proper impeller bolt torque specifications and proper spacer for Honda engine only.)

14.When impeller is installed, slide belt into drive pulley and adjust wire belt guide as shown on page 13 (see fig. 10 & 11).

15.Reattach nozzle and both caster brackets in reverse order of removal.

16.Check operator's bail to ensure that it operates properly. (If not, see drive adjustments on page 13). Note: Drive must completely disengage with bail released and must engage when bail is depressed within 1.0" (25.4mm) of the operator's handle.

17.Reinstall all belt guards.

18.Reconnect spark plug wire.

Chain Lubrication: Using S.A.E. 30 weight oil or equivalent. See maintenance schedule.

Grease: Wheels, Casters, and Rear Axle Bearings.

Tire air pressure: Check at regular intervals & maintain: Rear SP 13" tires at 14 psi. (9.8 kPa).

Part No 830542

12

Form No F062007A

Page 12
Image 12
Billy Goat VQ902SPH, VQ1002SP owner manual Periodic Maintenance

VQ902SPH, VQ1002SP specifications

The Billy Goat VQ902SPH and VQ1002SP are two powerful and efficient vacuum systems designed for homeowners and professional landscapers alike. These vacuum units are built to cater to outdoor cleanup needs, particularly for leaf collection and debris management, making them essential tools in maintaining a pristine landscape.

One of the standout features of both models is their robust engine. The VQ902SPH is equipped with a 9.0 HP Honda engine, while the VQ1002SP boasts a 10.0 HP engine. These powerful engines deliver impressive suction capabilities, allowing for easy collection of a variety of debris sizes, from leaves and grass clippings to larger twigs. The high-performance engines ensure that users can tackle large areas efficiently without the need for frequent stops.

Both units come with a large, high-capacity debris bag, which minimizes downtime by reducing the frequency of emptying. The VQ902SPH features a 30-bushel capacity, while the VQ1002SP's bag offers even more spacious storage. This means users can collect more debris in one go, making the cleanup process faster and more convenient.

An important consideration in outdoor equipment is maneuverability. Both vacuums incorporate a user-friendly design, featuring large, durable wheels that allow for easy navigation across various terrains. The ergonomic handle design ensures comfortable operation, reducing fatigue during extended use. Additionally, these models include a convenient tow-behind option for those who need to attach them to a tractor or ATV, enhancing versatility.

The innovative Cyclonic Filtration System used in the VQ902SPH and VQ1002SP improves air flow and performance, preventing clogging and allowing for consistent suction power throughout the operation. This tech ensures that dust and debris are collected efficiently without compromising the vacuum's functionality.

Another notable characteristic of both models is their all-steel construction, which provides durability and longevity. Whether encountering rough outdoor environments or consistent use, these vacuums are built to withstand the rigors of outdoor tasks.

In conclusion, the Billy Goat VQ902SPH and VQ1002SP are formidable tools for anyone looking to maintain their outdoor spaces effectively. With powerful engines, large debris capacity, superior maneuverability, and durable construction, these vacuum units deliver excellent performance, making them invaluable for efficient yard maintenance and cleanup.