TROUBLESHOOTING

Problem

Possible causes

Remedy

 

 

 

 

Nozzle worn

Replace nozzle

 

Water ￿lter fouled

Clean ￿lter (￿g.5)

 

Water supply pressure low

Turn on water supply tap fully

Pump does not reach working

Air being sucked into system

Check tightness of hose ￿ttings

pressure

 

Switch o￿ the appliance and keep depressing and releas-

 

Air in pump

ing the gun trigger until the water comes out in a steady

 

 

￿ow. Switch the appliance back on again.

 

Adjustable nozzle not positioned correctly

Turn the adjustable nozzle (E) (+) (￿g.3)

 

Water intake from external tank

Connect appliance to the mains water supply

Pressure drops during use

Intake water too hot

Reduce temperature

 

Nozzle clogged

Clean nozzle (￿g.5)

 

Insu￿cient power supply

Check that the voltage of the mains power supply line is

 

the same as that on the plate (￿g.2)

 

 

Motor “sounds” but fails to start

Voltage loss due to use of extension cable

Check characteristics of extension cable

 

Appliance not used for a long period of time

Contact your nearest Authorized Service Centre

 

Problems with AS device

Contact your nearest Authorized Service Centre

 

No electrical power

Check that the plug is ￿rmly in the socket and that the

 

mains voltage supply is present (*)

 

 

Motor fails to start

Problems with AS device

Contact your nearest Authorized Service Centre

 

 

 

 

Appliance not used for a long period of time

Using the tool (L) unjam the motor from the hole at the

 

rear of the appliance (in models with this feature) (￿g.5)

 

 

Water leakage

Seals worn

Have the seals replaced at your nearest Authorized

Service Centre

 

 

Appliance noisy

Water too hot

Reduce temperature (see technical data

Oil leakage

Seals worn

Contact your nearest Authorized Service Centre

AS versions only: motor starts

Nozzle clogged

Clean nozzle (￿g.5)

 

 

even with gun trigger is released

High pressure system or pump hydraulic circuit not

Contact your nearest Authorized Service Centre

 

watertight

 

 

AS versions only: no water delivery

 

 

when gun trigger is depressed

Nozzle clogged

Clean nozzle (￿g.5)

(with supply hose connected)

 

 

If the motor starts and does not restart during operation, wait 2-3 minutes before repeating the start-up procedure (overload cutout has been tripped). If the problem recurs more than once, contact your nearest Authorized Service Centre.