| 1 | FEATURES |
|
| A.) Red LED (Light Emitting |
|
| Diode) |
| A | B.) Green LED |
| B | C.) On/Off Button |
|
| |
3/4” Stud Sensor | C | Cover |
|
| D.) Battery Compartment |
INSTRUCTION MANUAL
D
2 | 3 |
|
Catalog No. FSSF100
THANK YOU FOR CHOOSING FIRESTORM!
GO TO
WWW.FIRESTORMTOOLS.COM/PRODUCTREGISTRATION
TO REGISTER YOUR NEW PRODUCT.
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON PLEASE CALL
BEFORE YOU CALL, HAVE THE CATALOG No. AND DATE CODE AVAILABLE. IN MOST CASES, A BLACK & DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE. IF YOU HAVE A SUGGESTION OR COMMENT, GIVE US A CALL. YOUR FEEDBACK IS VITAL TO BLACK & DECKER.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
VEA EL ESPAÑOL EN LA CONTRAPORTADA.
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
Cat No. FSSF100 Form # 90503117 (MAR. ‘06) Copyright © 2006 Black & Decker Printed in China
WARNING: To reduce the risk of injury, user must read and understand instruction manual.
SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS
•Do not operate the stud sensor in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
•Use the stud sensor only with the specifically designated batteries. Use of any other batteries may create a risk of fire.
OPERATING INSTRUCTIONS
CAUTION: Use caution when drilling, nailing or cutting into walls, floors and ceilings which may contain electrical wiring or pipes. These items may be detected by the Stud Finder in the same manner in which studs are detected. Because studs are normally spaced 16 inches or 24 inches apart and are
INSTALLING THE BATTERY
Remove the battery compartment cover (D) by pressing down in the center of the cover and pulling back. Insert two fresh AA batteries making sure to match (+) and
CALIBRATION AND SCANNING
1.) Hold unit straight up and down and place flat against wall as shown in Figure 2.
2.) Press in and hold the stud sensor ON/OFF button (C). a.) The upper red LED (A) will light,
b.) The unit will beep once while it is calibrating, c.) The bottom green LED (B) will light.
3.) Slide sensor slowly, (Figure 3,) horizontally across surface of wall without lifting or tilting.
4.) The upper red LED will light and a beeper will sound when an edge is detected , mark that spot (Figure 4).
Repeat this cycle coming from the other direction and again mark the spot where the upper red LED lights and beeper sounds.
Measure between the two marks made on the wall and the center will coincide with the center of the stud.
TIPS FOR OPTIMUM USE
•Test batteries before each use. Press and hold the on/off switch until the green LED lights. Then move your free hand toward the back of the unit. The red light should illuminate and then go out as you move your hand away from the unit. Replace the batteries if the red LED does not illuminate.
•Hold stud sensor straight up and down.
•Because studs are normally spaced 16 inches or 24 inches apart and are
•Metal or wood studs can be detected through up to 3/4” drywall.
•Avoid materials which have inconsistent density such as:
•Carpeting and padding
•Ceramic floor tile
•Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular wallpaper or fabric will scan with no difference in function.
•Walls that are freshly painted and are still damp.
•Excessively thick plaster and lath.
MAINTENANCE
Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid.
IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment (other than those listed in this manual) should be performed by authorized service centers or other qualified service personnel, always using identical replacement parts.
WARNING: The use of any accessory not recommended for use with this tool could be hazardous.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
4
TROUBLESHOOTING
|
| Problem |
| Possible Cause | Solution |
|
| ||
|
| • LEDs do not light. |
| • Weak battery. | • Replace with fresh batteries. |
|
| ||
|
|
|
| • Nothing to detect in that | • Start again moving farther to either |
|
| ||
|
|
|
| area. | side. |
|
| ||
|
|
|
| • Check mode. May have |
|
|
| ||
|
|
|
| been calibrated over a |
|
|
| ||
|
|
|
| stud. |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| • LED lights and sound |
|
|
| ||||
|
| • Wall thickness is over | • Thickness must be less than 3/4 |
|
| ||||
|
| stay on. |
| 3/4 inch thick. |
| inch to calibrate and work properly. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| • Upper LED lights in RED |
| • Voltage of two AA |
|
| • Replace with fresh batteries. |
|
|
|
| and sound stays on. |
| batteries has dropped |
|
|
|
| |
|
|
|
| below 2.2 volts. |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • LEDs light in too many |
| • Detects other objects | • Because studs are normally |
|
| ||
|
| places. |
| besides studs. | spaced 16 inches or 24 inches apart |
|
| ||
|
|
|
| • Electrical wiring and | and are |
|
| ||
|
|
|
| metal or plastic pipes | of anything closer together or of a |
|
| ||
|
|
|
| may be near or touching | different width. |
|
| ||
|
|
|
| back surface of wall. |
|
|
|
SERVICE INFORMATION
All Black & Decker Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the Black & Decker location nearest you. To find your local service location, refer to the yellow page directory under
FULL TWO-YEAR HOME USE WARRANTY
Black & Decker (U.S.) Inc. warrants this product for two years against any defects in material or workmanship. The defective product will be replaced or repaired at no charge in either of two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it was purchased (provided that the store is a participating retailer). Returns should be made within the time period of the retailer’s policy for exchanges (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges.
The second option is to take or send the product (prepaid) to a Black & Decker owned or authorized Service Center for repair or replacement at our option. Proof of purchase may be required.Black & Decker owned and authorized Service Centers are listed under
This warranty does not apply to accessories. This warranty gives you specific legal rights and you may have other rights which vary from state to state or province to province. Should you have any questions, contact the manager of your nearest Black & Decker Service Center.
This product is not intended for commercial use.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call
SPECIAL WARRANTY NOTE TO CONTRACTORS:
FIRESTORMTM branded products are offered as high end consumer home use tools and carry
aHOME USE WARRANTY. These tools are designed, manufactured and tested to meet or exceed the needs of the
performance well beyond their two year warranty. However, if you use tools for a living and use FIRESTORMTM branded products or any of Black & Decker’s other Consumer Home Use tools ON THE JOBSITE you should know that they CANNOT BE COVERED UNDER OUR
WARRANTY.
Imported by |
|
| |
Black & Decker (U.S.) Inc., |
| See | |
701 | E. Joppa Rd. |
| – Yellow Pages – |
Towson, | MD 21286 U.S.A. |
| for Service & Sales |