Black Box ACS236A, ACS235A manual Setting the Jumpers in the Local Module Optional

Models: ACS236A ACS235A

1 103
Download 103 pages 46.58 Kb
Page 17
Image 17

SERVSWITCH™ BRAND FIBER KVM EXTENDERS

3.2 Setting the Jumpers in the Local Module (Optional)

There are six user-settable jumpers inside the Local Module of the ServSwitch Brand Fiber KVM Extender. They control these options:

Whether the Local Module transmits VGA (default) or RGB video signals to the Remote Module, and if RGB, which signals and how (jumpers JP6, JP10, and JP11).

Whether the Local Module transmits HSYNC (default) or CSYNC to the Remote Module (jumper JP2).

Whether the Local Module uses automatic (default) or manual gain control (jumper JP3).

Whether the Local Module expects to transmit into 62.5/125-µm (default) or 50/125-µm fiber (jumper JP5).

If you need to set the unit for a non-default option, open the Local Module—being sure to take all reasonable precautions against static electricity—by unscrewing the upper part of its casing. (The jumper locations on the motherboard are shown in Figure 3-1.) Then set your desired jumpers as described in Sections 3.2.1, 3.2.2, 3.2.3, and/or 3.2.4, and then close the unit back up.

JP6

JP10

JP2

JP3

JP11

JP5

A

A

Figure 3-1. The locations of the ACS235A Local Module’s jumpers.

16

Page 17
Image 17
Black Box ACS236A manual Setting the Jumpers in the Local Module Optional, Locations of the ACS235A Local Module’s jumpers