3.10 Avoiding general rack mounting problems
3.10.1 Elevated operating ambient temperature
The operating ambient temperature of the rack environment may be greater than the
room ambient when installing into a closed or multi-unit rack assembly. So install the
equipment in an environment compatible with the maximum rated ambient
temperature.
3.10.2 Reduced airflow
Install the equipment in a rack in such a way that the amount of airflow required for
safe operation is not compromised.
3.10.3 Mechanical loading
Mount the equipment in the rack in such a way that a hazardous condition is not
achieved due to uneven mechanical loading.
3.10.4 Circuit overloading
When connecting the equipment to the supply circuit, consider the effect that
overloading of circuits might have on over-current protection and supply wiring.
Reliable earthing of rack-mounted equipment should be maintained. Give attention to
supply connections other than direct connections to the branch circuit (e.g. use of
power strips).
3.11 Rack mounting the ServSwitch Panther
Length of the screws used for connection of the bracket to the ServSwitch Panther unit
shall not exceed 5 mm.
Use the L-shaped brackets and screws provided to mount the ServSwitch Panther on a
server rack as illustrated below.
Insert
screws to
connect to
rack
Insert screws to connect
to Switch side panel
POWER
100-250 VAC 50/60 Hz 12345678
10 11 12 13 14 15 169
COMPUTER
Figure 7 Connecting the L-shaped bracket