Express Ethernet Switch: LB9017A-R3

 

ACT

Flashing

Transmitting

or

receiving

 

 

 

data

 

 

 

 

 

 

 

ACT stands for ACTIVITY

 

 

 

Off

Neither

transmitting

nor

 

 

 

receiving data

 

 

 

 

 

 

 

Port LED

LNK/ACT

On

A valid network connection

 

 

 

LNK stands for LINK

 

 

 

 

Flashing

Transmitting

or

receiving

 

 

 

data

 

 

 

 

 

 

 

ACT stands for ACTIVITY

 

 

 

Off

Neither

connection

nor

 

 

 

activity

 

 

 

 

 

 

 

 

 

SPEED

On

A valid 100Mbps connection

 

 

 

 

 

 

 

Off

A valid 10Mbps connection

 

 

 

 

 

 

 

 

 

 

 

 

100FX

LNK

On

A valid network connection

Port

 

 

LNK stands for LINK

 

 

LED

 

Off

No connection

 

 

 

 

 

 

 

 

 

 

ACT

Flashing

Transmitting

or

receiving

 

 

 

data

 

 

 

 

 

 

 

ACT stands for ACTIVITY

 

 

 

Off

Neither

transmitting

nor

 

 

 

receiving data

 

 

 

 

 

 

 

 

 

 

 

Installation

Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

-The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 50 degrees Celsius).

-The relative humidity should be less than 90 percent, non-condensing.

-Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.

-Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes on each side of the switch or on the rear of the equipment.

-The power outlet should be within 6 feet ( 1.8 meters ) of the switch.