LMC100A-SC-R2 LMC100A-RJ-R2
LMC100AE-SC-R2 LMC100AE-RJ-R2
LMC100A-SMSC-R2 LMC100A-SMSC-XLH-R2 LMC100AE-SMSC-R2 LMC100AE-SMSC-XLH-R2
LMC100A-R2LMC100A-SMRJ-R2
LMC100AE-R2 LMC100AE-SMRJ-R2
LMC100A-SM-R2 LMC100A-SMSC-SLH-R2
LMC100AE-SM-R2 LMC100AE-SMSC-SLH-R2 LMC100A-SMSC-LH-R2 LMC100A-LC LMC100AE-SMSC-LH-R2 LMC100AE-LC
LMC100A-SMLC
LMC100AE-SMLC
FlexPoint™ 10/100
Overview and Description:
The FlexPoint 10/100 converts between Fast Ethernet fiber 100Base-Fx and 10Base-T or 100Base-Tx twisted pair (RJ45 UTP) cabling. It operates in half duplex (HD) or full duplex (FD).
The following FlexPoint 10/100 models are described here:
Model | Fiber Type | Distance |
LMC100A-SC-R2 | 1310nm, MM, SC 2km / 1.2 mi. |
LMC100AE-SC-R2 | 1310nm, MM, SC | 2km / 1.2 mi. |
LMC100A-SMSC-R2 | 1310nm, SM, SC | 28km / 17.4 mi. |
LMC100AE-SMSC-R2 | 1310nm, SM, SC | 28km / 17.4 mi. |
LMC100A-R2 | 1310nm, MM, ST | 2km / 1.2 mi. |
LMC100AE-R2 | 1310nm, MM, ST | 2km / 1.2 mi. |
LMC100A-SM-R2 | 1310nm, SM, ST | 28km / 17.4 mi. |
LMC100AE-SM-R2 | 1310nm, SM, ST | 28km / 17.4 mi. |
LMC100A-SMSC-LH-R2 | 1310nm, SM, SC | 58km / 35 mi. |
LMC100AE-SMSC-LH-R2 | 1310nm, SM, SC | 58km / 35 mi. |
LMC100A-RJ-R2 | 1310nm, MM, MTRJ 2km / 1.2 mi. |
LMC100AE-RJ-R2 | 1310nm, MM, MTRJ 2km / 1.2 mi. |
LMC100A-SMSC-XLH-R2 | 1550nm, SM, SC | 85km / 52.8 mi. |
LMC100AE-SMSC-XLH-R2 | 1550nm, SM, SC | 85km / 52.8 mi. |
LMC100A-SMRJ-R2 | 1310nm,SM,MTRJ | 28km / 17.4 mi. |
LMC100AE-SMRJ-R2 | 1310nm, SM, MTRJ | 28km / 17.4 mi. |
LMC100A-SMSC-SLH-R2 | 1550nm, SM, SC | 110km/68mi. |
aListed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.
2. This product should always be used only with the Supplied Power Unit.
WARNING!
Before inserting the Power Adapter, verify that the power on the unit is appropriate
for yourAC line voltage source.
Mounting and Cable Attachment:
The FlexPoint 10/100 can be solo-mounted using a wall-mounting kit, or rack-mounted using a 5-position shelf or a high-density 14-unit FlexPoint Powered Chassis.
Attach the FlexPoint 10/100 UTP via a category 5 cable to a 10Base-T or 100Base-Tx Ethernet device.
Attach the FlexPoint 10/100 fiber via cable to a 100Base-Fx Fast Ethernet device. The FlexPoint transmit (Tx) must attach to the receive side on other device; the receive (Rx) must attach to the transmit.
Switch Settings:
“RJ45 Cross-Over” Switch:
When connecting the UTP to a hub or switch, set switch to “Straight-Through” (factory setting). When connecting to a workstation, set it to “Cross-Over.”
the “UTP 10/UTP 100” switch determines the speed of operation for the UTP port. When set to “UTP 100” (factory setting), the UTP port will operate at 100 Mbps. When set to “UTP 10” the UTP port will operate at 10 Mbps. Adjust the 10/100 Mbps switch to the speed of the connecting device and check for link status.
“UTP Full Duplex/UTP Half Duplex” Switch:
When the “Auto/Manual” switch is in “Manual” position, the “UTP Full Duplex/UTP Half Duplex” switch determines the duplex operation mode for the UTP port. When set to “Full Duplex” (factory setting), the UTP port will operate in full duplex. When set to “Half Duplex” the UTP port will operate in half duplex. Adjust the half/full-duplex switch to accommodate the connecting device and check for link status.
Half duplex must be used when connecting to a hub. Full duplex should be used when connecting switches or between a switch and a full-duplex workstation.
“Fiber Full Duplex/Fiber Half Duplex” Switch:
Since the IEEE 802.3 standard defines the Ethernet 10Base-FL fiber differently than the Fast Ethernet 100Base-Fx, it should be noted that they are incompatible. The FlexPoint 10/100 supports 100Base-Fx only. It operates in a half- or full-duplex mode of operation. This switch controls the half/full-duplex
CUSTOMER SUPPORT INFORMATION
LED Indicators:
Order toll-freein the U.S.: Call 877-877-BBOX(outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week; Call 724-746-5500or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com
E-mail:info@blackbox.com
LMC100AE-SMSC-SLH-R21550nm, SM, SC | 110km/68mi. |
LMC100A-LC | 1310nm, MM, LC | 2km / 1.2mi. |
LMC100AE-LC | 1310nm, MM, LC | 2km / 1.2mi. |
LMC100A-SMLC | 1310nm, SM, LC | 28km/17.4mi. |
LMC100AE-SMLC | 1310nm, SM, LC | 28km/17.4mi |
Installation and Configuration:
Power Adapter Notice:
1.When Using in a stand-alone configuration, this product is intended to be and must be used only with
TRADEMARKS USED IN THIS MANUAL
“UTP Auto/UTP Manual” Switch:
Setting the switch to “Auto” (factory setting) enables the UTP port to determine the speed and duplex mode automatically. If the connected device cannot provide the proper signal to indicate its own mode of operation, the “Manual” switch should be used. This feature allows connections with devices that do not auto-negotiate properly.
“UTP 10/UTP 100” Switch:
When the “Auto/Manual” switch is in “Manual” position,
NORMAS OFICIALES MEXICANAS (NOM)
operation of the fiber port.
Half duplex should be used when connecting to a hub (with a shared/non-switched fiber port) or a workstation that supports only half-duplex. Full duplex can be used when connecting to a switch or a workstation that supports full-duplex operation.
©Copyright 2011. Black Box Corporation. All rights reserved.
1000 Park Drive · Lawrence, PA 15055-1018
724-746-5500 · Fax 724-746-0746
12. Precación debe ser tomada de tal manera que la tierra fisica |
LED | Color | Description |
Power: | Yellow | Power applied |
UTP Auto: | Green | Auto-Negotiation enabled |
UTP FDx: | Green | Full-Duplex detected |
UTP Link: | Green | Link / Data received |
UTP 10: | Yellow | 10 Mbps link detected |
UTP 100: | Green | 100 Mbps link detected |
Fiber FDx: | Green | Full-Duplex selected |
F/O Link: | Green | Link / Data received |
SPECIFICATIONS: | |
Protocol: | | IEEE 802.3 |
Connectors & Cables: | |
Twisted Pair UTP: | RJ45, Category 5 or higher |
Fiber: | | SC, ST or MT-RJ |
Multimode: | | 50/125, 62.5/125, 100/140μm |
Single-mode: | 9/125μm |
Supported Distances: | Half-Duplex Full-Duplex |
Twisted Pair UTP: | 100m/328ft. 100m/328ft. |
MM1310nm fiber: 412m/1,350ft. 2km/1.2mi.
SM 1310nm fiber: 412m/1,350ft. 28km/16.8mi.
SM 1310nm LH fiber: 412m/1,350ft. 58km/36mi.
SM 1310nm XLH fiber: 412m/1,350ft. 85km/52.8 mi.
SM 1310nm SLH fiber: 412m/1,350ft. 110km/68.4 mi.
Dimensions / Weight: | W:3.0”xD:4.0”xH:1.0” / 6oz. |
Power: | 9VDC/500mA or 5VDC/750mA |
Temperature: | 0 to 40 degrees C |
Humidity: | 0-90% (non-condensing) |
Black Box and the Double Diamon logo are registered trademarks of
BBTechnologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCYINTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to be cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numéirques de las classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
ELECTRICAL SAFETY STATEMENT
1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2.Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3.Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4.Todas las instrucciones de operación y uso deben ser seguidas.
5.El aparato eléctrico no deberá ser usado cerca del agua— por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6.El aparato eléctrico debe ser usado únicamente con carritos o pedelstales que sean recomendados por el fabricante.
7.El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8.Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9.El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra or superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10.El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u ostros aparatos (incluyendo amplificadores) que producen calor.
11.El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
| y la polarización del equipo no sea eliminada. |
13. | Los cables de la fuente de poder deben ser guiados de tal |
| manera que no sean pisados ni pellizcados por objetos |
| colocados sobre o contra ellos, poniendo particular |
| atención a los contactos y receptáculos donde salen del |
| aparato. |
14. | El equipo eléctrico debe ser limpiado únicamente de |
| acuerdo a las recomendaciones del fabricante. |
15. | En caso de existir, una antena externa deberá ser localizada |
| lejos de las lineas de energia. |
16. | El cable de corriente deberá ser desconectado del cuando |
| el equipo no sea usado por un largo periodo de tiempo. |
17. | Cuidado debe ser tomado de tal manera que objectos |
| liquidos no sean derramados sobre la cubierta u orificios |
| de ventilación. |
18. | Servicio por personal calificado deberá ser provisto |
| cuando: |
| A: El cable de poder o el contacto ha sido dañado; u |
| B: Objectos han caído o líquido ha sido derramado dentro |
| del aparato; o |
| C: El aparato ha sido expuesto a la lluvia; o |
| D: El aparato parece no operar normalmente o muestra un |
| cambio en su desempeño; o |
| E: El aparto ha sido tirado o su cubierta ha sido dañada. |
LMC100A-SC-R2, version 2
040-01009-R21B 3/11