18-Slot Rackmount Chassis
Installation Guide
LMC5001A — LMC5002A
Master Module.
Installing 18-Slot Rackmount Chassis
Before installing any SNMP Manageable Modules and/or Master Modules into the
Rackmount Installation Instructions
To install a rackmountable
First, mount the RETMA mounting ears to the chassis with the supplied hardware. Then locate a suitable location in the rack for installation and secure the
When installing the chassis in an equipment rack, be sure to observe the following precautions to prevent electrical or mechanical damage:
Stay within the chassis power rating to prevent overload of supply circuits or damage to overcurrent protection and supply wiring.
Maintain reliable earth ground, especially when connecting to
1
power strip instead of directly to branch circuit.
Protect your chassis from exposure to sunlight and electrical or magnetic fields.
Ensure that the equipment rack remains stable, even with the addition of the chassis and its associated cabling.
Tabletop Installation Instructions
Be sure that the unit is placed on a suitable flat surface, leaving some space at the back of the unit to accommodate cooling. Attach the cables between the chassis and each device that will be interconnected, then plug the chassis into a reliable, filtered power source.
Configuring and Installing Modules
Refer to the installation guide shipped with the SNMP Manageable Module for configuration information. Master Modules come ready to install.
The process for installing these modules is simple. Remove the blank bracket covering the slot where you’ll be installing the module. Slide the module into the chassis, via the cardguides, until the module is seated securely in the connector. Secure the module to the chassis by tightening the captive screws.
NOTE: The first slot, located closest to the
Otherwise, this slot must remain empty for the chassis and the SNMP Manageable Modules to function properly. The 18 slots to the right of the management slot are for SNMP Manageable Modules. Do not install a SNMP Manageable Module in the management slot or vice versa. SNMP Manageable Modules may,
however, be installed in any order within the 18 slots.
Figure 1: Installing a SNMP Manageable Module in an 18-Slot Rackmount Chassis