Black Box LMC5001A Connecting a Managed Chassis, LED Operation, Installing Power Supply Modules

Models: LMC5001A

1 2
Download 2 pages 62.79 Kb
Page 2
Image 2
Connecting a Managed Chassis

Connecting a Managed Chassis

A managed 18-Slot Rackmount Chassis is connected to the LAN via an external 10Base-T hub connection. Connect a managed chassis to the network by plugging one end of a twisted pair cable into the port labeled “LAN” on the Master Module. Plug the other end of the twisted pair cable into a device (e.g., switch, hub, etc.) in your existing 10 Mbps Ethernet network.

LED Operation

SNMP Manageable Modules and Master Modules feature diagnostic LEDs that provide information to help determine where failures reside when they occur in your network. Refer to the installation guide shipped with the module for LED information.

Installing Power Supply Modules

18-Slot Rackmount Chassis ships with one Power Supply Module installed. It can operate on either AC or DC power, depending upon the Power Supply Module(s) used. A second, redundant Power Supply Module may be installed by removing the blank faceplate covering the second slot on the rear of the unit. Note that both Power Supply Modules must be of the same type — AC and DC cannot be mixed. When removing a Power Supply Module for replacement, UNPLUG THE POWER CORD to that module before sliding it out of the chassis.

Black Box Customer Service

Call: (724) 746-5500Phone orders 24 hours a day, 7:00 AM Monday to midnight Friday; 8:00 AM to 4:00 PM Saturday (EST)

Fax: (724) 746-0746 or in North America 1-800-321-0746

Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018

Technical Support and fax orders 24 hours a day.

Specifications

Environmental:
Operating Temperature: 32° - 104° F (0° - 40° C)Storage Temperature: 22° - 160° F (-6° - 71° C)Humidity: 5 - 95% (non-condensing)
Power:
AC Input Load: 100-240 VAC ±10%, 0.8/0.4A max.DC Input Load: -48 VDC, 1.5A max.
Chassis Dimensions:

4.58” H x 17.42” W x 9.13” D (11.63cm H x 44.25cm W x 23.19cm D) 12.9 lbs (5.9 kg)

Heat Generation:
250 BTU/hr. maximum
Electrostatic Discharge Precautions

Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions when installing or handling an add-in module or any board assembly.

1)Do not remove unit from its protective packaging until you’re ready to install it.

2)Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap, maintain grounded contact with the system unit throughout any procedure requiring ESD protection.

WARNING! Integrated circuits and fiber optic components are extremely susceptible to electro- static discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices.

3)Hold boards by the edges only; do not touch the electronic components or gold connectors.

4)After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the board over any surface.

Warranty

Please contact Black Box for complete warranty information.

Federal Communications Commission Radio Frequency Interference Statement

This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.

Safety Certifications

UL: Listed to UL1950 and CSA 22.2, No. 950, Safety of Information Technology Equipment, Including Electrical Business Equipment.

CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (89/336/EEC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (73/23/EEC). Certified to EN 60950, Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact Black Box.

1000 Park Drive • Lawrence, PA 15055-1018 USA

TEL: (724) 746-5500 • FAX: (724) 873-7049 info@blackbox.com • www.blackbox.com

© 2000 Black Box Corp. All rights reserved.

The information in this document is subject to change without notice. Black Box assumes no responsibility for any errors that may appear in this document. Product names are trademarks of the manufacturer. Other brands or product names may be trademarks and are the property of their respective companies.

Document Number 50-80935BB-00 A0