SERVICING — OPERATIONAL ADJUSTMENTS

BREW

BREW

QUALITY

DRIPOUT

AFTER HOURS

TIMER

TEMP

TIMER

TIMER

TIMER

(IN SECONDS)

(IN °F)

(IN 5 MIN INCR) (IN SECONDS) (IN ONE HR INCR)

210

194

70

 

60

3

TEMP WATER

 

 

 

 

 

 

PROBE LEVEL

 

185

20

 

 

 

PROBE

 

 

 

 

 

100 320

OFF 205

OFF 120

30

90

OFF

6

UNDER

TOP COVER

A

 

 

 

B

 

 

 

C

 

 

 

D

 

 

 

E

 

 

 

 

 

 

 

 

A.Adjust Brew Time

B.Adjust Brew Temperature

C.Adjust Quality Timer

D.Adjust Dripout Timer

E.Adjust After Hours Timer

CAUTION:

Electric Shock Hazard

Unplug or disconnect the brewer from electric power before removing the top cover

IMPORTANT: Adjustments must be performed by a qualified technician ONLY.

1.Access the Controls: All adjustments on the E-Max™ LX may be accessed by removing the top cover or top warmer station from the brewer. The adjustments are directly behind the front panel.

2.Adjust Brew Time: The time the brew solenoid is open maybe adjusted by turning the shaft of the left-most control (A). Turning the shaft clockwise increases the time. Ten degrees of rotation is approximately equal to seven seconds change. Adjust until a complete brew is achieved without overflowing the airpot or server.

3.Adjust Brew Temperature: Ideal brewing temperature is 195ºF to 205ºF. Realistically, the maximum brew temperature is the local boiling temperature minus 10ºF. To adjust the temperature, turn the shaft of the second control (B). Turning the shaft clockwise increases temperature. Fifteen degrees of rotation is approximately equal to 1-1/4ºF.

4.Quality Timer: (not used on airpot and thermal brewers).

5.Adjust Dripout Timer: This feature disables the brew switch for an amount of time to allow all water to finish dripping through the grounds. The length of time may be adjusted by turning the shaft of the fourth control (D). Turning the shaft clockwise increases the time. Ten degrees of rotation is approximately equal to 2-1/2 seconds.

6.Adjust After Hours Timer: This feature places the brewer into an energy-saver mode if no brew has been initiated for a length of time. Time may be adjusted by turning the shaft of the fifth control (E). Turning the shaft clockwise increases the time. Turning the shaft fully counter- clockwise turns the After Hours function off. Adjustment is in one hours increments.

9