![TROUBLESHOOTING SUGGESTIONS](/images/new-backgrounds/61002/6100223x1.webp)
|
| TROUBLESHOOTING SUGGESTIONS |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| SYMPTOM |
|
|
| POSSIBLE CAUSE |
| SUGGESTED REMEDY |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Water won’t heat |
|
|
| Brewer unplugged or circuit |
| Check power supply cord |
|
| |||
|
|
|
|
|
|
| breaker tripped |
| Check / reset circuit breaker |
|
| |||
|
|
|
|
|
|
| Thermostat set too low |
| Set for desired temperature |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Allow to cool |
|
| ||||
|
|
|
|
|
|
|
|
|
|
| Reset |
|
| |
|
|
|
|
|
|
| Damaged internal component or |
| Examine wiring & connectors, |
|
| |||
|
|
|
|
|
|
| wiring |
| thermostat and heating element |
|
| |||
|
|
|
|
|
|
|
|
|
|
| Repair/replace as needed |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Trips |
|
|
| No water or too little water |
| Be sure to add sufficient water |
|
| |||
|
|
|
|
|
|
| added at |
| prior to energizing |
|
| |||
|
|
| Coffee level low |
|
|
| Not enough water poured in |
| Increase water amount |
|
| |||
|
|
|
|
|
|
| Too much coffee grounds |
| Adjust amount of grounds |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Coffee level too high or low |
|
|
| Timer out of adjustment |
| Adjust timer |
|
| |||
|
|
| (automatic) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brew chamber overflows |
|
|
| Too many filter papers or wrong |
| Use one (1) genuine Bloomfield |
|
| |||
|
|
|
|
|
|
| filter paper |
| filter per brew |
|
| |||
|
|
|
|
|
|
| Brew chamber dispense hole |
| Thoroughly clean brew chamber |
|
| |||
|
|
|
|
|
|
| plugged |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Too much coffee or too fine a |
| Adjust coffee amount and grind |
|
| |||
|
|
|
|
|
|
| grind |
|
|
|
|
| ||
|
|
| Sprays water from brew head |
|
|
| Spray gasket missing or |
| Check/reinstall gasket on |
|
| |||
|
|
| incorrectly |
|
|
| improperly installed |
| INSIDE of brew head |
|
| |||
|
|
|
|
|
|
| Spray disk plugged |
| Clean spray disk |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| No brew (automatic) |
|
|
| Water supply OFF |
| Turn water supply ON |
|
| |||
|
|
|
|
|
|
| Water line strainer plugged |
| Clean strainer |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Water filter (if used) plugged |
| Replace filter element |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Bad BREW switch |
| Replace switch |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Damaged internal component or |
| Examine wiring & connectors, |
|
| |||
|
|
|
|
|
|
| wiring |
| brew switch and solenoid |
|
| |||
|
|
|
|
|
|
|
|
|
|
| Repair/replace as needed |
|
| |
|
|
| No flow from hot water faucet |
|
|
| Faucet valve turned OFF |
| Turn faucet valve ON |
|
| |||
|
|
|
|
|
|
| Faucet plugged |
| Disassemble faucet, clean |
|
| |||
|
|
| Poor coffee quality |
|
|
| Water not hot enough |
| Adjust water temp |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Also: |
|
|
|
|
| ||
|
|
|
|
|
|
| Keep brewer, airpots and servers |
| clean. |
|
|
| ||
|
|
|
|
|
|
| Install a taste and odor filter in water supply, and replace |
|
|
| ||||
|
|
|
|
|
|
| cartridges regularly. |
|
|
|
| |||
|
|
|
|
|
|
| Use a quality coffee with a consistent roast. Use proper grind and |
|
|
| ||||
|
|
|
|
|
|
| amount of coffee per brew. |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
601 75815 Owners Manual Integrity Decanter Brewers