TROUBLESHOOTING SUGGESTIONS
PROBLEM | POSSIBLE CAUSE | SUGGESTED REMEDY | |
|
|
| |
Unit will not operate | Disconnected from electric power | Reconnect to electric power | |
(no indicators lights lit) |
| Reset circuit breaker for unit | |
|
|
| |
Unit will not operate | Fire suppression system not set | Contact an authorized Ansul® distributor for repairs | |
(buzzer sounds) |
|
| |
|
|
| |
CHECK FILTER light lit | HEPA air filter or grease baffle not in position | Properly install HEPA filter and grease baffle | |
|
|
| |
REPLACE FILTERS light lit | HEPA air filter and charcoal filters nearing | Arrange to replace both HEPA and charcoal filters in | |
| end of service life | a timely manner | |
|
|
| |
SERVICE REQUIRED light lit | HEPA air filter and charcoal filters plugged | Replace both HEPA and charcoal filters | |
(fryer not operating) |
|
| |
Fire damper in exhaust collar has closed | Contact an authorized Wells service agent for | ||
| |||
|
| repairs | |
|
|
| |
| One or more vacuum sensing lines or ports | Contact an authorized Wells service agent for | |
| plugged | repairs | |
|
|
| |
| NOTE: If, after 10 seconds, there is insufficient airflow for proper operation, SERVICE REQUIRED | ||
| light will illuminate and fryer will be | ||
| Press FRYER POWER SWITCH to OFF, then back to FRYER to reset system. | ||
|
|
| |
|
| NOTE: | |
|
| FILTERS are the only user serviceable components | |
|
| in this ventilator hood system. For all problems that | |
|
| cannot be remedied by servicing the filters, contact: | |
|
| Fryer or ventilator section - authorized Wells | |
|
| service agency | |
|
| Fire suppression system - authorized Ansul® | |
|
| distributor |
IMPORTANT:
Contact ANSUL® for fire suppression system installation,
Ansul Incorporated | |
One Station Street |
|
Marinette, WI | website http;//www.ansul.com |
IMPORTANT:
Parts used in the Ansul® fire suppression system are not serviceable by the owner/operator. Procedures for servicing fire suppression equipment are described in:
ANSUL®
NOTE:
ANSUL® Manual 41807 and Wells Bulletin 301646 are intended for use by authorized Ansul® service personnel only.
M381 301603 OpM (Supplemental) NFPA Hood