Extron electronic DVS 304 manual Front Panel Lockout Executive Modes, System Reset

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 30
Image 30
System Reset

System Reset

For a scaler reset, the DVS 304 can return to default values by holding down the Input 1 button while simultaneously plugging in the power cord. The System Reset message will be displayed on the LCD screen.

Front Panel Lockout (Executive Modes)

To prevent accidental changes to settings, press the Menu and Next buttons simultaneously for 2 seconds to enable the DVS 304’s front panel lockout mode, also known as executive mode 1.

Executive mode 1 locks all front panel functions except input switching and preset recall. The menu system returns to the default menu within 10 seconds. The DVS 304’s front panel is affected by executive mode, but the IR 902 remote is not. See “IR 902 Infrared Remote Control” later in this guide for information.

When executive mode 1 is active, all functions and adjustments can still be made through RS-232 control. For details on RS-232 control, see “Communications and Control”.

To disable executive mode 1, press the Menu and Next buttons simultaneously for 2 seconds. See the flowchart below.

Enable Executive Mode

Default Cycle

2 sec.

INPUT 1

COMPOSITE

2 sec.

OUTPUT

1024 x 768@60

Press for

2 seconds*

Menu Next

EXE MODE

ENABLED

10sec. timeout

Disable Executive Mode

Default Cycle

2 sec.

INPUT 1

COMPOSITE

2 sec.

OUTPUT

1024 x 768@60

Press for 2 seconds*

Menu Next

EXE MODE

DISABLED

10sec. timeout

Figure 25. Front Panel Lockout

Executive mode 2 locks all front panel functions completely. This mode can be enabled or disabled by SIS commands only.

DVS 304 Series • Operation

25

Page 30
Image 30
Extron electronic manual Front Panel Lockout Executive Modes, System Reset, DVS 304 Series • Operation