Extron electronic manual Command, DVS 304 Series • SIS Communication and Control

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 48
Image 48
Manual background

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

 

 

 

On Screen Display (OSD) duration

 

 

Select speed

20*X9*#

Dur X9* ]

Set the OSD duration

View speed

20#

X9* ]

View the on screen display time.

 

 

 

Text label (OSD) (Input 4 only)

 

 

Write name

E X8$NI]

Nam 4X8$}

Write text X8$ for input 4.

Read name

ENI]

X8$}

View text label for input 4

 

 

 

 

PIP size

 

 

 

PIP size

16*X10%#

Pmd X10%]

Select size of PIP window.

View

16#

X10%]

View PIP window size.

 

 

 

 

PIP mode

 

 

 

PIP on

17*X10)#

Pip X10)]

PIP off

17*0#

Pip 0]

View

17#

X10)]

Turn PIP mode on with PIP window from input X10).

Turn PIP mode off.

View selection status (on or off).

Manual background NOTE: When PIP is active, all controls apply to the PIP window. The main window cannot be modified while PIP window is displayed.

Swap (when PIP mode is “On”)

%

Tke0]

Swap content between main and PIP window.

PIP mode audio follow (audio model only)

Set

19*X10^#

Aud X10^]

Select audio follow setting in PIP mode.

View

19#

X10^]

View audio follow status.

General information

 

 

 

I/i

Vid X7! • Aud X7! • Typ X7#• Std X8!• Pre X8! X8! X8! • Sdi X7!]

Query firmware version

 

 

 

Q/q

x.xx]

View the firmware version.

Query part number

 

 

 

N/n

60-1027-01/-02

View the part number.

 

 

/-03/-04]

 

View internal temperature

 

 

 

20S

X8@]

View internal temp. in degrees Celsius.

NOTE: X7! = Input selection

1 to 4

 

 

X7# = Input video format

1 to 9 (see page 35)

 

 

X8! = Input standard

0 = none, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM, - = RGB or YUVp/HDTV

 

X8@ = Internal temperature (in degrees Celsius)

 

 

X8$ = Text label/preset name

Up to 16 characters

 

 

X9* = OSD display setup:

0 to 5 seconds in 1 second steps

 

 

X10) = PIP window input selection

0 to 4

 

X10% = PIP window size X10^ = PIP audio setup

1= 1/4, 2 = 1/9, 3 = 1/16, 4 = 1/25, 5 = side by side normal, 6 = side by side full screen 1 = follow main, 2= follow PIP, 3 = toggle