Extron electronic manual DVS 304 Series • SIS Communication and Control, E Cc

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 56
Image 56
E CC }

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

Set Direct Access port map 24 Reset Direct Access port map 24 Disable Direct Access port map 24 Read Direct Access port map 24

E{port #}MD}

W{port #}MD

Pmd{port #}]

E2001MD}

W2001MD

Pmt02001]

E0MD}

W0MD

Pmd00000]

EMD}

WMD

{port #}]

DVS 304 Series • SIS Communication and Control

Listing connections

Get connection listing

E CC }

WCC

(See below.)

Remote client IP address: port number, time/date when connection was made, total connection time ]

Remote client IP address: port number, time/date when connection was made, total connection time ]

Remote client IP address: port number, time/date when connection was made, total connection time ]

...

Total clients • connections available ]]

Unit Web responses: HTML sample code var connections = new Array ();

connections [1] = ‘Client IP1, timedate 1, uptime 1’; connections [2] = ‘Client IP2, timedate 2, uptime 2’; connections [3] = ‘Client IP3, timedate 3, uptime 3’;

...

connections [n] = ‘Client IPn, timedate n, uptime n’; connections [n + 1] = ‘total clients, connections available’;

Manual background NOTE: X2@ = Verbose/Response Mode (Default = 0 for Telnet connections; 1 for RS-232 host control). 0 = clear/none, 1 = verbose mode, 2 = tagged responses for queries, 3 = verbose mode

and tagged responses for queries. If tagged responses is enabled, all read commands will return the constant string + the data, like setting the value does (for example command: Esc CN

} response: Ipnx12]).

X5@ = Connection’s security level: 0 = anonymous, 1 – 10=extended security levels 1 thru 10, 11 = user, 12 = administrator.

51