Extron electronic manual Command, DVS 304 Series • SIS Communication and Control

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 49
Image 49
Manual background

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

Front panel security lockout (Executive Mode)

Enable

1X

Exe1]

Disable

0x

Exe0]

View status

X

X%]

Allow limited front panel adjustments only.

Allow adjustments/selections to be made from front panel.

Show mode status. (0= disabled, 1= enabled)

SDI field flip

Standard

73*0#

Flp 0]

 

Flip fields

73*1#

Flp 1]

 

View

73#

X%]

(0= standard, 1= flipped)

 

 

 

 

Enhanced mode

 

 

 

Enable

52*1#

Enh X%]

 

Disable

52*0#

Enh X%]

 

View mode

52#

X%]

(0= disabled, 1= enabled)

 

 

 

 

Refresh lock

 

 

 

Enable

77*1#

Rfl 1]

 

Disable

77*0#

Rfl 0]

 

View status

77#

X%]

(0= disabled, 1= enabled)

 

 

 

 

Auto memory

 

 

 

Enable

1M

Aut1]

 

Disable

0M

Aut0]

 

View status

M

X%]

(0= disabled, 1= enabled)

 

 

 

 

Aspect mode

 

 

 

Enable Fill mode

99*1#

Ful1]

Starts Fill mode.

Enable Follow mode

99*0#

Ful0]

Starts Follow mode.

View status

99#

X10(]

(0= Follow, 1= Fill)

 

 

 

 

NOTE: X%

= On/off

0

= off/disable, 1 = on/enable

X10(

= Aspect ratio

0

= Follow, 1 = Fill

DVS 304

 

 

 

 

 

 

 

Settings saved for

16 per input

(64 total)

 

Auto Memory

 

 

 

 

 

 

 

 

Aspect ratio

Film mode

H/V start

 

 

 

 

Phase

Total pixels

H/V active

H/V pan

 

 

 

 

Zoom

 

 

 

 

 

 

 

H/V size

Bright/cont

Detail

H/V position

 

 

 

 

Color/tint

 

 

 

 

 

 

 

DVS 304 Series • SIS Communication and Control

44

Page 49
Image 49