Extron electronic Information requests, DVS 304 Series SIS Communication and, Event control

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 51
Image 51
Information requests

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

Query updated firmware

4Q

4Q

X1! ]

version

 

 

 

Example:

4Q

4Q

1.01 * (1.46-DVS 304

 

 

 

Series -Mon, 17 Jan

 

 

 

2005 17:03:46 GMT)

Use this command to find out which version of firmware has been uploaded into the processor post-factory.

In this example, firmware version is 1.01, kernel version 1.46, for DVS 304, dated 1 Jan, 2005..

Information requests

Request processor part number

N

N

Request model name

1I

1I

Request model description

2I

2I

Request system memory usage

3I

3I

Request user memory usage

4I

4I

60-736-XX ]

DVS 304 X ]

Extron Electronics

Digital Video Scaler ]

#Bytes used out of #Kbytes ]

#Bytes used out of #Kbytes ]

Show processor part number.

Show processor model name.

Show type of unit.

Show amount of memory used and total available memory for system operations.

Show amount of user memory used and total available user memory.

DVS 304 Series • SIS Communication and

Event control

Read event memory buffer 27

Write event to memory buffer24 27

Read string from event buffer memory 27

Write string to event buffer memory24 27

Start events24 27

Stop events24 27

Read number of events running

E X3%, X3^, X3&, X3*

WX3%%2C X3^%2C

X5$ ]

E}

X3&%2C X3* E

 

E X3%, X3^, X3&,

W X3%%2C X3^%2C

Ewr X3%, X3( ]

X3*, X3( E}

X3&%2C X3*%2CX3( E

 

E X3%, X3^, X3&, X4$ FE}

WX3%%2C X3^%2C

{string} ]

 

X3&%2C X4$ FE

 

E X3(,X3%,X3^,X3& FE}

W X3(%2C X3%%2C

Ewr X3%, X3(]

 

X3^%2C X3&FE

 

E1AE}

W1AE

Ego ]

E0AE}

W0AE

Est ]

EAE}

WAE

Enm## ]

Read the contents X5$ of a specific section of a memory buffer for event number X3%.

Write event X3% to buffer X3^, offset by X3&. Include data X3( , size X3*.

Read string from event X3%, buffer X3^, offset by X3&, X4$ bytes.

Write data string X3( from event X3%, buffer X3^, offset by X3&.

Initiate all programmed events.

Stop all programmed events.

## = number of events running.

Control 46

NOTE: X1! = Version number listed to 2 decimal places

X3%

= Event number

range: 0 to 99

X3^

= Event buffer

0 = receive, 1 = unified, 2 = data, 3 = NVRAM

X3&

= Event buffer offset

0 to MaxBufferSize

X3*

= Event data size

b = bit, B = byte (8 bits), S = short (16 bits), L = long (32 bits) This parameter is case sensitive.

X3(= Event data to write

 

X4$

= Number of bytes to read

1 to 24 max

X5$

= ASCII digit(s) representing the numeric value of the data element read from the event buffer (leading zeros are suppressed)