Extron electronic DVS 304 manual Removing the Sync to Matrix Script, Click Remove Script

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 33
Image 33
Removing the Sync to Matrix Script

f.Click the Take button to tie the DVS 304’s input to the selected switcher output. The program creates a custom script that is then be loaded onto the DVS 304. The Status box updates with the status of the script on the DVS 304, showing if the DVS 304’s script is connected to the matrix switcher, and showing the current tie associated with the selected output.

Using the DVS and Matrix Switcher After the DVS is Synchronized to the Matrix Switcher

After completing step 4, above, ensure the following is done when using the DVS with the matrix:

Perform all input switching using the matrix switcher. A 1-second RGB delay on the matrix is recommended to minimize the appearance of a glitch in the output while the

DVS locks onto the new signal.

The DVS senses when the matrix switcher changes input ties, and the DVS recalls the matching input preset, so input presets need not be recalled manually.

The DVS 304 and the matrix switcher must remain on the same subnet. Do not change the matrix switcher’s IP address. If the IP address of the matrix is altered, repeat step 4 above.

Removing the Sync to Matrix Script

If the Sync to Matrix feature is no longer being used, the script can be removed from the DVS by the following steps:

1.Open the Signal Processing Products Control Program and connect to the DVS via IP (not RS-232).

2.Under the Tools menu, select Sync DVS 304 to Matrix Switcher... . The

Sync DVS 304 to Matrix Switcher window opens.

3.Click Remove Script.

DVS 304 Series • Operation

28

Page 33
Image 33
Extron electronic manual Removing the Sync to Matrix Script, Click Remove Script, DVS 304 Series • Operation