DVS

SIS Command and Response Table for IP Control Port

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

Ethernet data port

Set current connection

E0 *X6( TC}

W 0 %2A X6( TC

Pti 0 * X6( ]

port timeout

 

 

 

View current connection

E0TC }

W 0TC

X6( ]

port timeout

 

 

 

Set global IP port timeout

E1 * X6( TC }

W 1%2AX6(TC

Pti1 * X6( ]

View global IP port

E1TC }

W 1TC

X6( ]

timeout

 

 

 

 

 

 

 

Firmware version requests

 

 

 

NOTE: An asterisk (*) after the version number indicates the version currently running. Caret (^) indicates bad checksum/invalid load. Question marks (?) indicate version not

loaded.

Query firmware version

Q or 1Q

Q or 1Q

X1! ]

Show the processor’s firmware version

number (X1!) to two decimal places. Gives the number of the currently running version of the user-updatable firmware.

304 Series • SIS Communication and Control

Query verbose version

0Q

0Q

All responses

information

 

 

from 2Q-3Q-4Q ]

Example:

1Q

1Q

1.01

Query bootstrap version

2Q

2Q

X1! ]

Example:

2Q

2Q

0.06

Query factory firmware

3Q

3Q

X1!(plus web ver.-

version

 

 

desc-date/time)]

Example:

3Q

3Q

1.00(1.37-DVS 304

 

 

 

Series -Fri, 12 Aug

 

 

 

2005 03:28:10 GMT)

Show bootstrap, factory-installed, and updated firmware versions. (See 2Q, 3Q, and 4Q, below.)

The bootstrap firmware is not user- replaceable but you may need this information for troubleshooting.

Factory-installed firmware is not user replaceable. This firmware is the version the processor reverts to after a mode 1 reset (see “Operation” section).

In this example, the factory firmware version is 1.00, (the kernel version 1.37), for the DVS 304, dated 12 August, 2005.

NOTE: X1!

= Version number (listed to 2 decimal places)

X6(

= The number of seconds before timeout on the IP connection: (min = 1; max = 65000; default = 30 = 300 seconds)

45

Page 50
Image 50