Extron electronic DVS 304 manual SIS Communication and Control, Host to Scaler Communications

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 35
Image 35
SIS Communication

SIS Communication

and Control

The DVS 304 can configured and controlled via a host computer or other device (such as a control system) attached to the rear panel RS-232 connector or the LAN port. Control is made using the Extron Simple Instruction Set (SIS) of commands, or by using the Signal Processing Products Control Program (SPPCP), or the devices internal HTML Web pages.

This section describes SIS communication and control. Topics that are covered include:

Host to Scaler Communications

Command and Responses

The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control and the rear panel RS-232 9-pin, D connector has the following pin assignments:

Pin

RS-232 Function

Description

1

Input #1

Contact closure

 

 

 

2

Tx

Transmit data

 

 

 

3

Rx

Receive data

 

 

 

4

Input #2

Contact closure

 

 

 

5

Gnd

Signal ground

 

 

 

6

Input #3

Contact closure

 

 

 

7

Input #4

Contact closure

 

 

 

8

-

No connection

 

 

 

9

-

Reserved

 

 

 

•Host to Scaler Communications NOTE: If contact closure is not in use, pins 1, 4, 6, and 7 should have no connection.

Host to Scaler Communications

SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the DVS 304 determines that a command is valid, it executes the command and sends a response to the host device. All responses from the scaler to the host end with a carriage return and a line feed (CR/LF = ]), signalling the end of the response character string (one or more characters).

Scaler-initiated Messages

When a local event such as a front panel selection or adjustment takes place, the DVS 304 scaler responds by sending a message to the host. No response is required from the host. Some scaler-initiated messages are listed here.

(C)Copyright 2010, Extron Electronics, DVS 304 series, Vx.xx ] The DVS 304 sends the copyright message when it first powers on. Vx.xx is the firmware version number.

In X! All ]

Reconfig ] (where X! is the input number). The DVS 304 sends this response when an input is switched or when a new signal is detected.

DVS 304 Series • SIS Communication and Control

30

Page 35
Image 35
Extron electronic DVS 304 manual SIS Communication and Control, Host to Scaler Communications, Scaler-initiatedMessages