Extron electronic manual DVS 304 Series • SIS Communication and Control, E X1$CI

Models: DVS 304

1 92
Download 92 pages 39.71 Kb
Page 54
Image 54
E X1$CI }

DVS 304 Series • SIS Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

 

 

 

 

 

Set IP address24

E X1$CI }

WX1$CI

Ipi • X1$ ]

X1$ = IP address (xxx.xxx.xxx.xxx).

 

 

 

 

Leading zeros in each of the four fields are

 

 

 

 

optional in setting values.

Read IP address24

ECI }

WCI

X1$]

Leading zeros in each of the four fields are

 

 

 

 

suppressed in returned values.

Read hardware

ECH }

WCH

X1*]

X1* = hardware media access control (MAC)

address (MAC)

 

 

 

address (xx-xx-xx-xx-xx-xx).

Set subnet mask24

E X1(CS}

WX1(CS

Ips•X1( ]

X1( is the subnet mask (xxx.xxx.xxx.xxx).

 

 

 

 

Syntax is the same as for the IP addresses.

 

 

 

 

Leading zeros are optional in setting values.

Read subnet mask

ECS} E

WCS

X1( ]

Leading zeros are suppressed.

Set gateway IP address24

E X1$CG}

W X1$CG

Ipg•X1$ ]

X1$ is the IP address. Leading zeros are

 

 

 

 

optional.

Read gateway IP address

ECG}

WCG

X1$ ]

 

Set broadcast mode

E X6$,X1$EB}

W X6$%2C X1$EB

BmdX6$, X1$ ]

 

Set administrator password 24

E X3#CA}

WX3#CA

Ipa•X3# ]

Set the administrator access password.

 

 

 

 

(X3# is 4-12 alphanumeric characters)

 

 

 

 

The password is case sensitive. Special

 

 

 

 

characters (spaces or symbols) are

 

 

 

 

not allowed.

Clear administrator

E•CA}

W%20CA

Ipa• ]

Clear/remove all passwords (administrator

password 24

 

 

 

and user)

Manual background NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the DVS 304 has not been configured yields an Manual background E14 response from the processor. If the administrator password is cleared (removed), the user password is also removed.

Read administrator password

ECA}

WCA

X3# ]

NOTE: X% = On/Off 0 = off/disable, 1 = on/enable

X1$

=

IP address (xxx.xxx.xxx.xxx); leading zeros in each of 4 fields are optional in setting values, and are suppressed in returned values.

X1*

=

Hardware (MAC) address (xx-xx-xx-xx-xxxx)

X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are optional in setting values in each of four fields, and are suppressed in returned values.

X3# = Password (12 characters = maximum length; no special characters are allowed).

X6$ = Broadcast repetition rate in seconds (0 – 255 max; default = 0 = clear). The response is returned with leading zeros. 1 – 11 = entry without password goes to the level

 

 

specified (if an admin password exists). The response as returned as 2-digits with a leading zero.

49

Page 54
Image 54
Extron electronic manual DVS 304 Series • SIS Communication and Control, E X1$CI