LRemote (RS-232/contact closure) port — This 9-pin connector provides for two- way RS-232 communication. See the “SIS Communication and Control” chapter for information on how to install and use the control software and SIS commands.

The default protocol is 9600 baud, 1 stop bit, no parity, and no flow control.

The rear panel RS-232 9-pin D female connector has the following pin assignments:

Pin

RS-232 Function

Description

1

Input 1

Contact closure

2

Tx

Transmit data

3

Rx

Receive data

4

Input 2

Contact closure

5

Ground

Signal ground

6

Input 3

Contact closure

7

Input 4

Contact closure

8

-

No connection

9

-

Reserved

Figure 7. RS-232 Pin-out

The Remote connector also provides a way to select an input using a remote contact closure device. Contact closure control uses pins on the RS-232 connector that are not used by the RS-232 interface (see preceding table).

To select a different input number using a contact closure device, short the pin for the desired input number to logic ground (pin 5).

NOTE: If contact closure is not in use, pins 1, 4, 6, and 7 should have no

connection.

DVS 304 Series • Cabling

8

Page 13
Image 13
Extron electronic DVS 304 manual Pin RS-232 Function Description, Ground Signal ground Input, No connection