DVS 304

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

 

 

 

 

 

Set user password14 24

E X3#CU}

WX3#CU

Ipu•X3# ]

Set the user access password

 

 

 

 

X3# is 4-12 alphanumeric characters.

 

 

 

 

The password is case sensitive. Special

 

 

 

 

characters (spaces or symbols) are

 

 

 

 

not allowed.

NOTE: A user password cannot be assigned if an administrator password does not exist.

Clear user password24

E•CU}

W%20CU

Ipu•]

This clears the user password only.

Read user password24

ECU}

WCU

X3#]

 

Set verbose mode24

E X2@CV}

W X2@CV

VrbX2@]

Set verbose mode.

NOTE: The processor can send out unsolicited information (such as notice of a volume or input change or a change in some other setting). That is called verbose

 

(wordy) relationship between the processor and a connected device. For a direct RS-232/422 connection, the processor is set for Verbose mode by default.

 

When the DVS 304 is connected via Ethernet, Verbose mode is disabled by default in order to reduce the amount of communication traffic on the network.

 

If you want to use the Verbose mode with a processor connected via Ethernet, this mode must be set to On each time you reconnect to the processor.

Read verbose mode

ECV}

WCV

X2@]

 

Read connection’s security

ECK}

WCK

X5@]

 

level

 

 

 

 

Series • SIS Communication and

Re-map port designations

Set Telnet port map 24

Reset Telnet port map 24

Disable Telnet port map 24

Read Telnet port map

Set Web port map 24

Reset Web port map 24

Disable Web port map 24

Read Web port map 24

E{port #}MT}

W{port #}MT

Pmt{port #}]

 

E23MT}

W23MT

Pmt00023]

Set Telnet to the default port (23)

E0MT}

W0MT

Pmt00000]

 

EMT}

WMT

{port #}]

 

E{port #}MH}

W{port #}MH

Pmh{port #}]

 

E80MH}

W80MH

Pmh00080]

 

E0MH}

W0MH

Pmh00000]

 

EMH}

WMH

{port #}]

Set Web port to default value of 80

Control 50

NOTE: X2@ = Verbose/response mode (Default = 0 for Telnet connections; 1 for RS-232 host control). 0 = clear/none, 1 = verbose mode, 2 = tagged responses for queries, 3 = verbose mode

and tagged responses for queries. If tagged responses are enabled, all read commands will return the constant string + the data, like setting the value does (for example command:

Esc CN } response: Ipn• x12]).

X3# = Password (12 characters = maximum length; no special characters are allowed)

X5@ = Connection’s security level: 0 = anonymous, 1 – 10=extended security levels 1 thru 10, 11 = user, 12 = administrator

Page 55
Image 55
Extron electronic DVS 304 manual WX3#CU, Re-map port designations, Emt, Emh