IP Configuration

IP Configuration

The IP Configuration menu displays the IP address of the unit, the Subnet mask, and Gateway IP address.

MEMORY PRESETS

MENU

IP

CONFIG

NEXT

 

 

I 196.168

 

 

 

P 254.254

 

 

 

 

 

 

 

 

 

 

View IP address of the unit.

NEXT

S255.255 M 000.000

View the subnet mask of the unit.

NEXT

 

 

G 000.000

 

NEXT

 

 

M 000.000

 

 

 

 

 

 

 

 

 

 

 

 

View gateway IP address of the unit.

Figure 19. IP Configuration Menu

To change an IP address, do the following:

1.Press and hold the Input 4 and Next buttons simultaneously for 2 seconds. This introduces the IP Setup mode.

2.Change the flashing octet selection by using the Adjust vertical ({) knob. Change the address by using Adjust horizontal ([) knob.

3.Press the Next button to select another address to set up (subnet mask or gateway IP).

4.Press the Menu button to save and exit.

The IP configuration menu “times out” and saves changes if there is no activity for over 10 seconds.

Advanced Configuration

The following flowchart provides an overview of the Advanced Configuration submenus and the options for each setting.

IP

CONFIG

MENU

NEXT

ASPECT MODE

FOLLOW

ADVANCED

NEXT

AUTO IMAGE

NEXT

BLUE MODE

NEXT

CONFIG

<OFF> ON

<OFF> ON

 

 

 

Aspect Mode

 

 

 

 

 

Sets if an input signal’s

 

 

 

 

 

aspect ratio is followed, or

 

 

 

 

if all inputs fill the entire

 

 

 

 

AUTO SWITCH

 

NEXT

 

 

RGB DELAY

 

NEXT

<OFF>

ON

 

 

 

0.0 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEXT

ouptut raster.

 

Auto imaging

 

Blue mode

 

• Fill

 

When auto image is on,

 

When set to on, only the

 

 

the unit automatically

 

 

 

 

sync and blue video

 

• Follow

 

 

 

 

sizes and centers each

 

 

 

 

signals are passed to the

 

 

 

new input.

 

 

 

 

 

display.

 

 

 

 

 

 

AUTO MEMORY

NEXT

REFRESH LOCK

NEXT

ENHANCE MODE

NEXT

<OFF> ON

<OFF> ON

<OFF> ON

 

 

 

Auto Memory

 

Refresh Lock

 

Enhance Mode

 

When set to on, the unit

 

When set to On, the

 

When set to On, the

 

automatically saves the

 

vertical ouptut rate locks

 

automatic gain control of

 

input and picture control

 

on to the incoming

 

the low resolution inputs

 

settings for each input.

 

vertical refresh rate.

 

is enabled.

 

Auto switching

The unit switches to the highest numbered input that has a signal present when auto switching is on.

TEST PATTERN

 

 

NEXT

OFF

 

 

 

 

 

 

 

 

 

Test patterns

Off

Crop

Alternating pixels

Color bars

RGB delay

Can be set from 0 to 5.0 seconds in 0.5 second steps.

OSD LABEL

2 sec.

On Screen Display label duration

Can be set from 0 OFF (no OSD) to 5 seconds in 1 second steps.