page no.
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Installing LP Gas Tank
To operate you will need (1)
Note: An empty standard outdoor fireplace LP gas tank weighs approximately
18 lbs. A
Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one.
Insert LP Gas Tank
WARNING: Make sure LP gas tank valve is closed. Close by turning valve clockwise.
Place precision filled LP gas tank upright into hole in outdoor fireplace body so it is arranged for vapor withdrawal.
Secure LP Gas Tank
Secure tank by sliding tank retainer wire around the LP gas tank.
Connect LP Gas Tank
Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it stops.
Disconnect LP Gas Tank
Before disconnecting make sure the LP gas tank valve is OFF.
Disconnect gas line to tank by turning knob counterclockwise until it is loose.
Operating Instructions
Checking for Leaks
WARNING: Before using this outdoor fireplace, make sure you have read, understand and are following all information provided in the Dangers and Warnings presented on page
2.Failure to follow those instructions can cause death, serious injury or property damage.
Burner Connections
Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.
WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
Make
Make sure control knob is “OFF”. Turn LP gas tank ON at valve.
Spoon leak check solution at all “x” locations
If any bubbles appear turn LP gas tank OFF, reconnect and
If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
Lighting
1.Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice.
A clogged burner tube can lead to a fire beneath the appliance.
2.Control knob must be in the “OFF” position.
3.Turn on gas at LP gas tank.
4.Push and turn control knob counterclockwise to “LOW”.
5.Press the igniter button repeatedly to light burner.
6.Release control knob after 5 seconds.
7.If ignition does not occur in 5 seconds, turn burner control knob “OFF”, wait 5 minutes, fan with newspaper or magazine, and repeat lighting procedure.
8.If igniter does not light burner, use a long match or long butane lighter.
a.Wearing Heat reistant gloves, position the lit long match or lit long butane lighter near the side of the burner.
b.Turn control knob counterclockwise to “LOW”.
c.Remove long match/long butane lighter.
9.After lighting, observe the burner flame, make sure all burner ports are lit and flame height matches illustration.
10.Adjust flame to desired flame with the control knob.
CAUTION: If burner flame goes out during operation, immediately turn the gas “OFF” and let the gas clear for about 5 minutes before
LP Gas | Burner |
Connection | venturi |
| LP Gas Valve |
Burners | with Orifice |
X
X
X
X
X
LP Gas Tank Valve
Control Knob
Match Placement
Proper flame height.