Bock Water heaters 73E Performance Specifications, And Roughing-In Dimensions, The recommended

Models: 241E 72E 541E 73E

1 8
Download 8 pages 28.51 Kb
Page 2
Image 2
PERFORMANCE SPECIFICATIONS

PERFORMANCE SPECIFICATIONS

stalled – do not block access to the burner, inspection door,

 

 

 

 

 

 

 

 

 

 

 

Leave ample room for servicing when the water heater is in-

AND ROUGHING-IN DIMENSIONS

handholes or controls. Leave room to pipe the unit and connect

CAUTION:

 

 

 

the fuel and electricity.

 

 

 

 

 

 

 

 

The recommended

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

water temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting for normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER SPECIFICATIONS

 

 

 

 

 

 

 

 

residential use is

 

 

 

MODEL/OEM #

 

NOZZLE

PRESSURE

 

 

 

 

 

120OF.

 

 

 

 

 

 

 

 

 

 

 

 

72E

 

CARLIN EZ-2HP/9833222J72E

1.25X70OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAYNE MSR/371-019B

 

1.50X80OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIELLO R35.5/C8512221

1.25X60OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73E

 

RIELLO 40F10/

 

1.25X60OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARLIN EZ-2HP/9833222J73E

1.50X70OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAYNE MSR/371-022B

 

1.75X80OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

190E

 

RIELLO 40F10/C8514109

1.50X60OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAYNE MSR/371-129B

 

1.35X70OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARLIN EZ-1/9682811J190E

1.35X70OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

241E

 

BECKETT AF

 

 

1.35X70OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARLIN EZ-2HP/9833111J241E

1.65X70OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

361E

 

WAYNE 371-024B

 

2.0X80OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARLIN 201CRD/98285000B361E

2.50X70OB

150 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

541E

 

WAYNE EH/371-026

 

3.00X80OA

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARLIN 201CRD/98285000B541E

4.00X70OB

130 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAYNE EH/371-028

 

4.50X80OB

100 PSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZES AND CAPACITIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(shipping weights are complete assembly, including burners and controls)

 

 

 

 

 

 

 

 

MODEL

STORAGE

BTUH

FIRING

STANDARD

MOTOR

SHIPPING WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

INPUT

RATE

VOLTAGE

STANDARD

ASME

 

 

 

 

 

 

 

 

 

72E

67 GAL.

199,000

1.50 GPH 120V 60HZ

1/7 HP

550 LBS.

 

––

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73E

67 GAL.

242,000

1.75 GPH 120V 60HZ

1/7 HP

550 LBS.

 

––

 

 

 

 

 

 

 

 

 

 

 

 

190E

113 GAL.

190,000

1.35 GPH 120V 60HZ

1/7 HP

690 LBS.

 

––

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

241E

109 GAL.

277,000

2.00 GPH 120V 60HZ

1/7 HP

925 LBS.

950 LBS.

 

 

 

 

 

 

 

 

 

 

361E

91 GAL.

415,000

3.00 GPH

120V 60HZ

1/4 HP

1105 LBS.

1125 LBS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72E

 

 

 

 

 

541E

83 GAL.

623,000

4.50 GPH 120V 60HZ

1/4 HP

1330 LBS.

1340 LBS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

73E, 190E, 241E, 361E

– 2 –

541E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* DL

/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LETNI

 

 

MODEL

 

A

 

B

 

C

 

D

 

E HOTOUTLETCOINLET DRAIN ALTRETURN

 

 

 

 

 

 

 

 

 

72E & 73E

 

58”

 

28”

 

20”

 

16”

 

8”

1 /2”*

1”

3/4”

1 /2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

1

 

 

 

190E

 

66 /4

 

311/2

 

20 /2

 

19”

 

6”

2”*

1”

3/4”

2”

 

 

 

 

 

1

 

 

1

 

1

 

19”

 

8”

2”*

1”

3/4”

2”

 

 

 

241E

 

67”

 

31

/2

 

22”

 

 

 

 

 

 

 

 

361E

 

67”

 

31

/2

 

26”

 

23”

 

9”

2”*

1”

3/4”

2”

 

 

 

541E

 

66”

 

 

1

 

30 /2

 

NA

 

10”

2”*

2”*

3/4”

2”

 

 

 

 

34”

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Nipple

 

not

 

furnished

 

 

** Under drain valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on 72E & 73E only

 

 

 

Page 2
Image 2
Bock Water heaters 73E Performance Specifications, And Roughing-In Dimensions, The recommended, water temperature, 120OF