![Energy Saver](/images/new-backgrounds/47163/471633x1.webp)
Energy Saver
Power Direct Vent
Independent Vent System
Gas Water Heaters
B
This product is available from:
F |
D G C A
E
(LN) LowNOx Burners | 1ST HR. | RECOVERY GPH @ | |||
|
| DEL GAL. | |||
|
|
| DEGREE RISE | ||
|
| @ 100° F |
| ||
|
|
|
|
| |
|
| RISE | 40° F | 100° F | 140° F |
150,000 BTUH | 201 | 364 | 145 | 104 | |
180,000 BTUH | 250 | 436 | 175 | 125 | |
220,000 BTUH | 298 | 533 | 213 | 152 | |
150,000 BTUH | 215 | 364 | 145 | 104 | |
180,000 BTUH | 245 | 436 | 175 | 125 | |
220,000 BTUH | 283 | 533 | 213 | 152 |
Propane Gas Inputs (LP) | 1ST HR. | RECOVERY GPH @ | |||
|
| DEL GAL. | |||
|
|
| DEGREE RISE | ||
|
| @ 100° F |
| ||
|
|
|
|
| |
|
| RISE | 40° F | 100° F | 140° F |
225,000 BTUH | 274 | 545 | 218 | 156 | |
225,000 BTUH | 288 | 545 | 218 | 156 |
|
|
|
|
|
|
|
|
|
|
| DIMENSIONS (INCHES) |
|
|
| SHIPPING WEIGHT | ||||
|
|
|
| RECOVERY GPH |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 1ST HR |
|
| C | D | E |
| G |
|
|
|
|
| ||||
|
|
| @ DEGREE RISE |
|
|
|
|
|
|
|
| ||||||||
|
| RATED | DEL GAL |
|
| TOP | F&R | F&R | F | TOP |
| GAS | RELIEF |
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||||||||
MODEL | STORAGE | INPUT | @ 100° F | 40° F |
|
| A | B | WATER | HOT | COLD | GAS | VENT | WATER | CONN. | VALVE | STD | ASME | |
NUMBER | (GAL) | (BTU/HR) | RISE | 100° F | 140° F | HEIGHT | DIA. | CONN. | CONN. | CONN. | CONN. | HEIGHT | CONN. | DIA. | OPEN. | (LBS) | (LBS) | ||
80 | 150,000 | 204 | 364 | 145 | 104 | 3/4 | 3/4 | 645 | N/A | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
80 | 199,999 | 253 | 485 | 194 | 139 | 3/4 | 3/4 | 645 | N/A | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
83 | 250,000 | 301 | 606 | 242 | 173 | 3/4 | 1 | 645 | 720 | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
100 | 150,000 | 219 | 364 | 145 | 104 | 3/4 | 3/4 | 735 | N/A | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
100 | 199,999 | 266 | 485 | 194 | 139 | 3/4 | 3/4 | 735 | N/A | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
100 | 250,000 | 312 | 606 | 242 | 173 | 3/4 | 1 | 735 | 815 | ||||||||||
2(R) | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Natural Gas use the suffix "NA", Example: |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
LP on |
|
|
|
|
|
|
|
| |||||||||||
ASME Construction available on the |
|
|
|
| |||||||||||||||
For Low NOx compliance to meet SCAQMD requirements, place an "LN" in the model number; Example: |
|
|
|
| |||||||||||||||
T=Top, F=Front, R=Rear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.
115V A.C. RequiredT&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed
Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi
Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.
Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or
www.bockwaterheaters.com